DT4572 X-Band Down Converter
Rev. 0
Remote Control
MM/DT4572.IOM
58
B.6.2.5 A
UTO
F
AULT
R
ECOVERY
The converter output is automatically muted in the event of a detected fault. Auto Fault
Recovery, if enabled, will cause the output signal to go active (unmuted) if all faults
clear. If disabled, the output will remain muted even after all faults clear until a
MUT_OFF command is received (see 4.8.2.4). If Auto Fault Recovery is enabled and the
converter detects the same fault more than five times in a five minute interval (ex:
multiple IFLO lock detect faults) the function reverts to DISABLED and the converter
remains muted. The default is ON.
Command
Details
Set Fault Recovery:
<DEV/AFR
_
xxx'cr'
xxx = ON or 0FF
Confirmation: >DEV/AFR
_
xxx'cr''lf']
Retrieve Status:
<DEV/AFR
_
'cr'
Confirmation: >DEV/AFR_xxx'cr''lf']
B.6.2.6 P
ROGRAM
P
RESET
This command is used to stores up to 32 preset frequency and attenuation settings.
Command
Details
Program Preset:
<DEV/PGM
_
nn
_
xxxxx.xxx_yy.yy'cr'
Confirmation: >DEV/PGM
_
nn_xxxxx.xxx_yy.yy'cr''lf']
Note:
nn = Preset Number = 01 to 32.
xxxx.xxx = Frequency = RF
Low
to RF
High
(for example, 7250.000 to 7750.000 MHz for
Model DT-4572).
yy.yy = Attenuator = 00.00 to 25.00.
B.6.2.7 D
ISPLAY ALL
P
RESETS
This command is used to display all programmed preset numbers.
Command
Details
Display Presets:
<DEV/DPS
_
'cr'
Confirmation: >DEV/DPS
_'
cr
'
P01 xxxxx.xxx yy.yy'cr'
to
P32 xxxxx.xxx yy.yy'cr''lf']
Where: xxxxx.xxx
=
Frequency
yy.yy= Attenuator
Note:
Only programmed preset numbers are returned. If no preset(s) is programmed, “No Pre-
Selects Programmed” is returned.
Содержание DT-4572
Страница 1: ...DT 4572 X Band Down Converter Installation and Operation Manual Part Number MN DT4572 IOM Rev 0 ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 48: ...DT4572 X Band Down Converter Rev 0 System Operation MM DT4572 IOM 30 NOTES ...
Страница 64: ...DT4572 X Band Down Converter Rev 0 Redundant System Operation MM DT4572 IOM 46 NOTES ...
Страница 88: ...DT4572 X Band Down Converter Rev 0 Remote Control MM DT4572 IOM 70 NOTES ...
Страница 98: ...DT4572 X Band Down Converter Rev 0 Maintenance and Troubleshooting MM DT4572 IOM 80 NOTES ...
Страница 102: ...2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 Phone 480 333 2161 FAX ...