DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Serial Interface Operation
Revision 2
8–18
8.7.2.21
FRM (Firmware Information)
Use FRM to query the firmware loaded in the current production unit. This
includes firmware numbers, versions, and release dates. This query replaces the
legacy FRW query.
Description
Details
Return Firmware Information:
<DEV/FRM_{cr}
Confirmation:
>DEV/FRM_{cr}
Boot: {cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
Bulk1: {cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
Bulk2: {cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}
FW-AAAAAAA B.B.BB DD/MM/YY{cr}{lf}]
where: FW-AAAAAAA = the firmware part number
B.B.BB = the version number
DD/MM/YY = Day/Month/Year firmware released
8.7.2.22
IMG (Firmware Image)
Use IMG to set or return selection of a valid bulk image as the next active boot
image.
Description
Details
Set Next FW Image:
<DEV/IMG_x{cr} where:
x = 1 or 2
Confirmation:
>DEV/IMG_x{cr}{lf}]
Return Active FW Image:
<DEV/IMG_{cr}
Confirmation:
>DEV/IMG_x{cr}{lf}]
Содержание DT-4500 Series
Страница 48: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Specifications Revision 2 2 12 Notes...
Страница 92: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Firmware Update Revision 2 5 16 Notes...
Страница 120: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Front Panel Operation Revision 2 6 28 Notes...
Страница 146: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Ethernet Interface Operation Revision 2 7 26 Notes...
Страница 180: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Serial Interface Operation Revision 2 8 34 Notes...
Страница 204: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Appendix B Revision 2 B 8 Notes...
Страница 205: ......
Страница 206: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...