LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Front Panel Operation
Revision 5
6–14
When an external reference oscillator is connected and set to other than 5 MHz
or 10 MHz, the following screen appears:
EXTERNAL REFERENCE FREQ
MUST BE 5/10 MHz
6.2.3.5
CONFIG: SPECT-INV (Spectrum Inversion)
Spectrum Inversion:
ConvA=NRM ConvB=INV
To set Spectrum Inversion operation:
Use the
[
][
]
arrow keys to select
ConvA or ConvB, and then use the
[
][
]
arrow keys to toggle the parameter as
NRM
(Normal) or
INV
(Invert). Press
[ENT]
when done.
6.2.4
(SELECT:) MONITOR Menu Branch
These examples are provided for reference only – the data that displays
on your system will vary depending on your actual operating conditions.
Five
read-only
information screens provide monitoring of a number of operating
voltage, temperature and tuning parameters. Use the
[
][
]
arrow keys to
page between screens.
Monitor A: iflo=08.2
rflo=01.6 tp=+32.1
Monitor B: iflo=08.1
rflo=01.6 tp=+30.2
These screens show the active Monitor A (Conv-A) and Monitor B (Conv-B) Up
and/or Down Converter IDU operating parameters, where:
•
iflo
= IF Lockout
•
rflo
= RF Lockout
•
tp
= Operating Temp (°C)
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...