LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Appendix B
Revision 5
B–8
Force Backup
Use the drop-down menu to select
Yes
, and then click
[Change]
to force the
redundant unit into standby mode.
The last section on this page displays the
read-only
Online
or
Offline
status for
each converter.
B.4
Redundancy Operations Using Serial Remote
Control
See
Chapter 8. SERIAL INTERFACE OPERATION
for detailed
information about using serial remote control commands and
queries.
The “FBU,” “RED,” and “SAM” remote commands and queries are provided for
LBC-4000 redundancy operation.
B.4.1
FBU (Force Backup Unit)
Command only. Use “FBU” to force switchover to the backup unit. Valid in
Manual redundancy mode only.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
FBU_
N/A
0 bytes
This command takes no arguments.
N/A
N/A
B.4.2
RED (Redundancy Mode)
Command or Query. Use “RED” to set or return the active redundancy mode.
Controller-to-Target
Instruction Code and Qualifier
Arguments for
Command or
Response to
Query
Description of Arguments
Target-to-Controller
Response
Command
Query
Command
Query
RED_
RED_
3 bytes,
alphabetic
Set or return in the form RED_yyy where:
yyy=ON (Redundancy is enabled) or OFF
(Redundancy is disabled)
RED_
RED_
Содержание CD-MNLBC4000
Страница 72: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Firmware Update Revision 5 5 16 Notes...
Страница 154: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix A Revision 5 A 8 Notes...
Страница 164: ...LBC 4000 L Band Up Down Converter System MN LBC4000 IOM Appendix B Revision 5 B 10 Notes...
Страница 165: ......
Страница 166: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...