Hold buttons for 5
seconds to enter the installer mode.
+
+
6. Installer parameters
To enter installer parameters please follow steps below. Please refer to parameters table description before any changes. Use
or
buttons to move
up or down between all parameters. Every change/selection confirm by button:
1
3
Use
or
to choose
code „49”.
Press
button to confirm.
Select installer parameter by or
buttons. Use
or
buttons to
change parameter value.
Confirm choice by
button.
4
2
dXX
Function
Parameter
Values
Description
Default
Values
d01
Control method
temperature
This parameter defines the algorithm of the room temperature control.
0
0
PWM (Pulse-width modulation) algorithm ensures reduction of overdrive
states and economic operation of the system. It is an advanced algorithm
designed to precisely maintain room temperature.
1
SPAN ± 0.5°C (± 1°F)
2
SPAN ± 1°C (± 1.5°F)
d02
Offset temperature
-3.0°C to
+ 3.0°C
Offset room temperature measuring is a function which allows user to
recalibrate internal thermostat’s temperature sensor by a given number of
degrees (in the range from -3,0 °C to 3,0 °C in 0,5°C steps).
0.0°C
d03
Using a floor temperature
sensor (S1, S2)
0
No sensor
0
1
Sensor is connected
d04
External sensor
used for air
or floor temperature
measurement
(Function is active,
when d03=1)
0
Thermostat measures the temperature only on the
external sensor
0
1
The sensor is used as a protection against
overheating the floor
3