15-2
Project #4
–
“Change Grandfather Clock Message”
This project removes: “CAT EIGHT HUNDRED REPEATER” from the grandfather clock message and
replace it with “W4XYZ REPEATER”. Substitute your call letters.
1.
Unlock the controller to place the controller in programming mode.
Key-up and enter: [1234567]
2.
Program the voice Message #8 with W4XYZ repeater.
Key-up and enter: [*3108 890 004 920 930 950 746 830 838 482 100 103]
3.
Lockup the controller to return to normal operation.
Key-up and enter: [*0]
Project #5
–
“Change the Port #1 CTCSS Logic active low”
This project changes the Port #1 CTCSS logic input from active high to active low COR and CTCSS
logic. At default all three CTCSS inputs are set for active high COR and CTCSS logic.
1.
Unlock the controller to place the controller in programming mode.
Key-up and enter: [1234567]
2.
Change the Port #1 CTCSS logic to active low.
Key-up and enter: [*3612]
3.
Lockup the controller to return to normal operation.
Key-up and enter: [*0]
Project #6
–
“Add a Fan to cool the repeater using the controller’s switch #1”
The fan will turn on when the transmitter turns on and remain on for an additional minute after the
transmitter turns off. Connect a small 12VDC relay to the controller. Connect one coil lead to J1-14
and the other lead to a source of +12VDC. Place a spike suppression diode across the coil with the
banded end on the +12V lead.
1.
Unlock the controller to place the controller in programming mode.
Key-up and enter: [1234567]
2.
Change Switch #1 to a fan control switch.
Key-up and enter: [*3912]
3.
Lockup the controller to return to normal operation.
Key-up and enter: [*0]
4.
Turn on Zone 6 Channel 5.
Key-up and enter: [100 6 1 1]
5.
Turn off Zone 5 Channel 1.
Key-up and enter: [100 5 1 1]
Project #7
–
“Place the controller in DTMF Access mode from midnight until 6:00 AM”
During the early morning hours a control operator may not be available to monitor the repeater.
Some repeater owners may choose to place the repeater into DTMF Access mode. The repeater will
appear to be a sleep but if the DTMF Access number is entered the repeater will wake up. The default
number is: [325]. After a period of inactivity the repeater will go back to sleep.
1.
Unlock the controller to place the controller in programming mode.
Key-up and enter: [1234567]
2.
Schedule DTMF Access to turn on at 11:59 PM every day.
Key-up and enter: [*1142 23 59 00] Key-up and enter: [*1742 1 * 1821]
3.
Schedule DTMF Access to turn off at 06:00 AM every day.
Key-up and enter: [*1143 06 00 00] Key-up and enter: [*1743 1 * 1820]
4.
Lockup the controller to return to normal operation.
Key-up and enter: [*0]
Содержание CAT-800
Страница 42: ...5 13 3634 SET PORT 3 CTCSS LOGIC COR OR CTCSS ACTIVE LO...
Страница 87: ...11 1 Chapter 11 Drawings CAT 800 Repeater Controller Board...
Страница 88: ...11 2 DR 800 Digital Audio Player...
Страница 90: ...12 2 CAT 800 Sheet 1 of 4...
Страница 91: ...12 3 CAT 800 Sheet 2 of 4...
Страница 92: ...12 4 Sheet 3 of 4...
Страница 93: ...12 5 Sheet 4 of 4...
Страница 94: ...12 6 DR 800 Digital Audio WAV Player Sheet 1 of 1...