4.3.2
HMI user interface description
The CDD6 door drive has a front panel that allows to activate different functional modes: Normal,
Inspection, Configuration.
MODE
NORMAL
INSPECTION
CONFIGURATION
Description
Normal mode (automatic):
the door drive executes the
commands from MLC
Inspection mode (manual):
the door drive executes
commands from the front
panel keys
Configuration mode: parameters
Programming
LED
S
NORMAL
ON
OFF
OFF
INSP
OFF
ON
OFF
CONFIG
OFF
OFF
ON
KEYS
1
Key 1 and key 4 pressed
together per t>3s:
Configuration mode access
ENTER
Access to parameter value
OR
Parameter value saving and
return to parameters list
2
Pressed and keep pressed
(t>3s):
Last alarm code showed (“no
AL” if no alarm present)
Door opening
Pressed and keep pressed
(t>5s) together key 3: enable
or disable Motor torque
+
Increase Parameter index,
OR
Increase Parameter value
3
Pressed for t>3s when last
alarm is showed: reset of the
last alarm codes (“no AL”)
Door closing
Pressed and keep pressed
(t>5s) together key 2: enable
or disable Motor torque
-
Decrease Parameter index,
OR
Decrease Parameter value
4
Access to Inspection mode (if
only key 4 pressed for t>1s)
Access to Configuration mode
(if key 1 and key 4 pressed
together for t>3s)
Return to Normal mode
ESC
Exit from parameter selection
OR
Exit from Configuration mode
and return to Normal mode
DISPLAY
Door drive status showed:
“- -“, “OP”, “CL”, “IM”, “AL”, ..
Door drive status showed:
“- -“, “OP”, “CL”, “IM”, “AL”, ..
Parameter list: “P” alternate to
the parameter index.
Parameter modification:
parameter value showed
NOTES
This is the default mode at the
power ON of the door drive.
ALL inputs are active
DOC and DCC signals from the
MLC are not active
Parameter selection: “P” showed
alternate to the parameter index
- Table 16: functional table of the CDD6 front panel -