• Click 

Level

. A dialogue window will appear on your screen.

• Select the required settings for 

Volume 

and

 Input sensitivity

 by moving the scroll bar

(keep the mouse button down).

• Click on the X in the title bar to close the dialogue window.

• Set the audio parameters of your computer by using the respective Windows pro-

grammes (such as the programme for your sound card).

• Click 

Off 

when you want to finish the audio transmission.

The sound card terminates the playing back. The transmission capacity taken up by the
audio signal until now will again be released for use by the video signal. This immediately
improves picture quality.

Video

When a connection with an ACom has been established, you can switch between the six
video inputs. You can determine the video play back quality. You have the choice between
a high-resolution and a lower-resolution mode.

The Common Intermediate Format (CIF) supports a local resolution of 288 lines x 352
dots. This is the resolution of the default setting.

The format Quarter CIF (QCIF) has a resolution of 144 lines x 176 dots.

Selection of the lower resolution may prove to be sensible if you prefer a higher frame
rate (refresh frequency) to a high resolution. The resolution of the video signal currently
received is identified in the field Video inside the control window: green indicates higher
resolution (CIF), yellow the lower resolution (QCIF).

Furthermore, you must find a compromise between the conflicting demands of high im-
age definition (sharp focus) and a rapid, “lifelike“ representation of movement inside the
picture.

If your priority is a high refresh frequency, the picture quality in terms of sharpness and
focus will decrease in direct proportion to the increase of movement in the camera range
(blurred and distorted images). If you prefer pictures with the highest possible sharpness
and a clear focus, this means that the refresh frequency decreases when there is move-
ment to be detected. If movement is anticipated only in a limited part of the frame, you
may be well advised to prioritise sharpness. The smart compression process is capable
of refreshing only the parts of the images concerned by (spatially constricted) move-
ments. The unchanged rest of the picture will be represented with the highest possible
degree of sharpness.

By selecting the option PiP (Picture in Picture) you can display the image of the local
camera as a part of the surveillance frame.

• Click on one of the fields 

Camera 

to receive the desired camera image or video signal.

• Define your choices by clicking the respective options.

• Move the scroll bar between 

Sharpness 

and 

Motion 

to create the right balance.

Configuration with CMCtrl

Содержание acom6

Страница 1: ...Installation Guide and Operational Manual Video Alarm System ACom6 Please read this manual before you install operate store or handle the device...

Страница 2: ...This Installation and Operational Manual edition 01 12 99 is valid for the models ACom6 ACom6A ACom6H and ACom6HA as of 1999 and the software CMCtrl version 4 15 as of 1998...

Страница 3: ...ymbols used in this Manual 7 Product Description Extent of Delivery 8 Functions and Features An Overview 9 Connections 10 Assembly Wall Mounting 12 Connections 13 Switch on switch off 17 Configuration...

Страница 4: ...c Settings 37 Telephone Numbers 41 Output actions 42 Input Actions 44 Recording 45 Changing the Settings 46 Operation Assembly 48 LEDs 48 Functional Test 49 MFD Control 49 Maintenance 51 Cleaning 51 P...

Страница 5: ...unctions If a hard disc is installed you can record video data Other applications are not permitted If you have studied this manual carefully and still have questions concerning the operation of the d...

Страница 6: ...have been inserted if the device has been in storage for a considerable time under adverse conditions or if it has been subjected to heavy transport strains If any or all of the preceding apply have t...

Страница 7: ...epair works Symbols used in this Manual Safety instructions in this manual are divided into two different categories A DANGER If you are ignoring safety instructions which are marked like this you are...

Страница 8: ...with a free serial interface and operating system Windows 95 98 NT Access to ISDN or Access to the analog phone network and a readily installed modem Pre conditions for Successful Operation Computer...

Страница 9: ...Digital Network All ACom devices have an integrated ISDN adapter Rapid transmission of large data volumes is best conducted simultaneously on both B channels of a basic ISDN connection S0 The system...

Страница 10: ...10 ACom6 Connections Product Description...

Страница 11: ...or video signals from a camera or another device 13 Video connection terminal Outputs for video signals to the connection with a local observation screen 14 Alarm connecting terminals 4 potential free...

Страница 12: ...sufficient space for lines and cables Ensure sufficient ventilation of the device For cable connections use only cables which have been part of the delivery or are otherwise suitable and which help t...

Страница 13: ...o cable 75 ohm BNC plug to the BNC socket of the ACom or Remove terminal block from the socket Put signal conductor on terminal V1 Put shield on terminal Connect additional cameras where applicable In...

Страница 14: ...ey would be with an ISDN line The system supports all modems with an asynchronous RS232 interface and which op erate with the Hayes command set Once you have connected the modem ACom auto matically re...

Страница 15: ...must not exceed 12 V En sure correct polarity Remove terminal block from socket Put conductors to the terminals in strict compliance with their polarity Ensure correct assignment Insert terminal bloc...

Страница 16: ...Loud speaker 5 Telephone receiver transmitter 6 Telephone receiver ear piece 7 Telephone receiver ear piece 8 common ground Remove terminal block from socket Put cables on the appropriate connections...

Страница 17: ...occurrences of excess voltage peaks of interference voltage and voltage losses in the electric network can be absorbed efficiently Insert screw terminal of the plug type power pack into the plug bar P...

Страница 18: ...nstalled on your computer The programme has been designed for the operating system Windows 95 98 NT System Conditions Computer with readily installed operating system Windows 95 98 NT 1 free serial in...

Страница 19: ...m deinstallation simply by deleting the entire directory Start end Programme Once you have completed the installation procedure successfully you will find the pro gramme icon in the folder NCTerm Conn...

Страница 20: ...ar The system menu of CMCtrl will appear on your screen Restore Restore programme window to its original size Move Move CMCtrl programme window with the cursor keys Minimize Reduce programme window in...

Страница 21: ...meters for the precise serial interface of the computer that you selected for the connection to the ACom Com Port Serial interface of the computer to which the ACom has been connected Baud Rate Transm...

Страница 22: ...desired option and then OK to confirm your selection The dialogue box will be closed Important A change of the default language will only take effect after the next start of CM Ctrl Send Address If t...

Страница 23: ...en established Yellow connection is in the process of being established or terminated List Panel Call Number The upper list panel consists of the call numbers dialled so far to enable easy and con ven...

Страница 24: ...Black not available Green available Yellow Modem is in the process of being initialised Blue only for GSM modem PIN correct but modem not yet booked in Red only for GSM modem incorrect PIN Red flashes...

Страница 25: ...er on Alarm Results page 29 Such additional information may include 1 Alarm information grey signal Alarm trigger has been rendered active white sign Alarm has been activated triggered V Video signal...

Страница 26: ...l begins its search for devices capable of configuration If a local ACom has been found the field Local Unit will light up in yellow If a connection has been established with a remote device the field...

Страница 27: ...djust the audio level of the ACom input and output in order to improve the quality Furthermore you can also activate the automatic audio transmission in the course of the establishment of a connection...

Страница 28: ...al currently received is identified in the field Video inside the control window green indicates higher resolution CIF yellow the lower resolution QCIF Furthermore you must find a compromise between t...

Страница 29: ...lso being displayed as grey symbols for instance V for video alarm In the case of an alarm the same symbol will appear in red see page 25 Alarm Stamping You can enter a text and select additional alar...

Страница 30: ...er alarm This may be useful when a key switch is being used to activate the system If this option is activated the alarm input 0 must itself be active red status panel to clear all other alarms You ca...

Страница 31: ...sensitivity must have been set at a value above zero Where applicable the master alarm must have been activated Important Carry out several tests if necessary to ensure that the video sensor functions...

Страница 32: ...ate the available switch outputs of the ACom individually and assign a brief text to them for easy and prompt identification Activate the switch outputs as required by clicking the respective fields F...

Страница 33: ...a lamp which has been turned on by an alarm is meant to remain switched on after the end of the alarm you would have to select the option Forever If a siren which has been switched on by an alarm is m...

Страница 34: ...ogether with the video im age on your screen after selection of the camera The text to be displayed will allow you to identify the camera site immediately If required the system can display the time o...

Страница 35: ...h a setting can be useful if you have activated the detection of movement and or the video alarm From the list box select the camera input you want to define as the default camera Video Source Select...

Страница 36: ...list boxes Click the control box if you want to switch the interfaces Datamode You can set different modes for the purposes of serial data communication The mode Transparent 1 is suitable for the con...

Страница 37: ...r his password If he cannot enter a valid password the process is terminated Once he has entered a valid password the ACom can either be operated in User or Serv ice mode Operation in Service mode mak...

Страница 38: ...to the GSM modem when a connection is established Click on PIN to enter your PIN A dialogue window will appear on your screen Enter the number in the text box New PIN and confirm your entry in the te...

Страница 39: ...re call number or the EAZ last number of your ISDN connection ISDN protocol You can perform different settings for the ISDN connection You may for instance define whether the connection from the ACom...

Страница 40: ...dow Read Save Configuration will appear on your screen Enter the file name and the corresponding path or click Search to change into the required directory Select the required file Click Start to load...

Страница 41: ...the list box for instance 01 A dialogue window will appear on your screen Enter the complete call number in the text box Call number If the call number belongs to an ACom under password protection ent...

Страница 42: ...the speed calling to be called first in the case of an alarm From the subsequent list boxes select alternative numbers to be called in case the prioritized connection cannot be established In the sam...

Страница 43: ...input via a door contact the output will switch on a siren Inputs and outputs of two ACom devices may also be cross connected to make the switch relays follow the inputs of the other device This allo...

Страница 44: ...remote ACom are used You can rule separately for every input whether a local or a remote video source is to be activated The setting does not cause any change Hold Function When several alarm sensors...

Страница 45: ...the hard disc You have the choice between a time triggered and an event triggered recording mode You can also define the type of recording individual pictures or film and the quality of recording The...

Страница 46: ...Click on Settings The window Recording will appear on your screen Active from to Period in which the recording mode in question is active Type Recording of individual picture frames or of films You s...

Страница 47: ...cording is meant to last Use the list box Pre Alarm to acti vate the ring recording mode If you have entered a period in this list box the ACom will save incoming video data in a ring loop memory Once...

Страница 48: ...lid Both flaps must snap in with a discernible clicking sound LEDs 1 Power lights up if the device is connected to the power supply 2 Detect lights up if the video sensor detects a movement in the vid...

Страница 49: ...re that the service switch is always switched to Betrieb Otherwise the password does not protect the ACom from unauthorized access any more MFD Control Modern telecommunications networks support Multi...

Страница 50: ...vate alarm 2 x 1 x Numbers 0 8 alarm inlet Deactivate alarm 2 x 0 x Numbers 0 8 alarm inlet Switch on relay 3 x 1 x Numbers 1 2 relay outlet Switch off relay 3 x 0 x Numbers 1 2 relay outlet Play back...

Страница 51: ...Disconnect the ACom first from the power supply and then from the ISDN Check what caused the defect in the first place before inserting a new fuse Only use a fuse with 250 V and 2 A tr If no cause fo...

Страница 52: ...which must be treated as hazardous industrial waste and discharged expertly and in compliance with legal rules and regulations Devices peripherals and accessories which are either faulty or not in us...

Страница 53: ...A f o l r t C M C r o f s r e t e m a r a p d r a d n a t s 1 y t i r a p o n s t i b a t a d 8 d u a B 0 0 2 9 1 r e w o p f f o n r u t y l t n e u q e s b u S t i b p o t s a r e t f a n i a g a n...

Страница 54: ...n e r u t c i p o N o t n o i s s i m s n a r t n o i t a t s t u o a r e m a c e v i t c e f e D k c e h c d n a r o t i n o m l a c o l t c e n n o C n o i t c n u f a r e m a c n o i t c e n n o c...

Страница 55: ...socket Video signal outlets 1 FBAS 1 0 VS S 75 Ohm Audio inlet 1 19 mVS S 1 67 VS S 15 kOhm 40 dBm0 1 13 mVS S 1 18 VS S 15 kOhm 40 dBm0 Audio outlet 1 2 2 VS S max 50 Ohm 2 5 20 dBm0 1 2 2 VS S max 2...

Страница 56: ...2 33 12 F 44 0 208 202 33 87 CBC Europe Ltd Ufficio Milano Via E Majorana 2 I 20054 Nova Milanese MI T 39 0 362 365079 F 39 0 362 40012 CBC Poland Sp z o o Ul G Morcinka 5 Paw 6 PL 01496 Warszawa T 48...

Отзывы: