3-02 

Aux 1 Output 

0.5 Second 

Latched 

20 Seconds 

Program 

3-03 

Aux 2 Output 

0.5 Second 

Latched 

60 Seconds 

Program 

3-04 

Aux 1 Output Control 

By Remote 

Arm 

Disarm 

Ignition Off 

3-05 

Aux 2 Output Control 

By Remote 

Arm 

Disarm 

Panic 

3-06 

Horn Mute Control on 

Remote 

Disabled 

Enabled 

  

  

3-07 

Sliding Door(Aux1, Aux2) 

Control for iDatalink 

Modules 

Off 

Unlock,  Factory 

Disarm,  

and Sliding Door 

Control 

 Factory Disarm and 
Sliding Door Control 

Only 

  

3-08 

CN 2 PIN 4 

Status 

Ignition 

Aux1 

Aux2 

3-09 

CN 2 PIN 5 

Rearm 

Ignition 

Aux1 

Aux2 

3-10 

CN 2 PIN 6 

Disarm 

Ignition 

Aux1 

Aux2 

3-11 

CN 2 PIN 7 

Horn 

Ignition 

Aux1 

Aux2 

 

Special Option Group 

 

  

Feature 

Setting Value (Seconds) 

Aux 1 output 

1- 99 seconds 

Aux 2 output 

1-99 seconds 

 
 

IMPORTANT: 

System must be unlocked before you can set options with the OP500 or remotes. 

 
*Once programmed, this feature requires activation from the remote. Please refer to the 
remote user manual or the option description below. 

 

Option Menu Descriptions 

 
1-01  

Unlock Before, Lock After Starting

 - If enabled, this option will unlock the doors before remote 

starting, start the vehicle, then lock the doors after the vehicle starts. It will then lock the doors 
again if the remote start run time expires and the vehicle shuts down. The third option locks the 
doors upon remote start shut down only. The fourth option turns on lock after remote start 
shutdown only. This feature is for vehicles that have factory alarms that need to be disarmed 
before remote starting such as Toyota and Lexus.  

 
1-02 

Lock / Unlock Pulse Duration

 

– This option changes the length of the lock and unlock ground 

pulses on the blue and blue/black wires on CN3. The default setting is for 0.8 seconds. Optional 
setting 2 changes the duration to a 2.5 second pulse. The third setting changes the duration to a 
short 0.125 second pulse setting. The fourth setting changes the duration to a 3.5 second pulse. 

 
1-03 

Double Pulse Locks

 

– This option changes the behavior of both the lock and/or unlock wires. 

This feature cannot be used with Option 1-04.   

 

Содержание Firstech CM800-S

Страница 1: ...rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device may accept any interference received including interference that may cause undesir...

Страница 2: ...ng on Option 2 04 6 Alternator Sensing Option 2 04 Setting 3 7 Assumed Timed Crank Option 2 04 Setting 4 7 Diesel Timer 8 CM800 S Firmware 8 CM800 S Wiring Schematic Remote Start 9 Option Programming...

Страница 3: ...eek professional installation Call 888 820 3690 or visit our website at www compustar com to locate your nearest dealer Caution The Manufacturer s warranty will be void if this product is installed by...

Страница 4: ...the system into Valet using the remote you must turn the ignition on and then tap the Lock and Trunk buttons System comes in Tachless Sensing Mode The CM800 S comes preprogrammed in No Tach Sensing Mo...

Страница 5: ...ghts will flash once confirming each additional remote The CM800 S can store up to three remotes Exiting Programming Programming is a timed sequence The parking lights will flash twice signaling the e...

Страница 6: ...wire on Connector 1 This wire is powered by an internal relay in the control module In the default position the jumper is set to 2nd Ignition 2nd Ignition is common on GM and Toyota vehicles and will...

Страница 7: ...Turn the ignition to the run position The stator wire should now test between 1 6V DC C Start the vehicle with the key The stator wire should now test between 12 14V DC at idle STEP 3 Process complet...

Страница 8: ...sel Timer to allow the vehicle s glow plug wire to heat up There are two time settings on this unit 7 or 18 seconds This will allow the ignition to power up and then crank once the time has expired an...

Страница 9: ...9 CM800 S Wiring Schematic Remote Start...

Страница 10: ...during remote start The behavior of this wire is selectable by a jumper inside the control module By default this wire powers up as a 2nd Ignition trigger It is changeable to a 2nd Starter or 2nd Acc...

Страница 11: ...This wire can also be programmed through the Option 3 11 It can be change to Ignition Auxiliary 1 or Auxiliary 2 output Pin 8 Gray Black Hood Pin negative input This input is a safety shut down and al...

Страница 12: ...verse polarity for trigger door lock systems Pin 5 Blue Black Lock 250mA negative output This is an optional output that will provide a pulse for locking doors System will lock doors IMPORTANT You mus...

Страница 13: ...Pulse Single Pulse Off Feature Default Setting I Optional Setting II Optional Setting III Optional Setting IV 2 01 Timer Start or Minimum interval between cold Start 3 Hour 1 5 Hour 2 02 Minimum Cran...

Страница 14: ...the option description below Option Menu Descriptions 1 01 Unlock Before Lock After Starting If enabled this option will unlock the doors before remote starting start the vehicle then lock the doors a...

Страница 15: ...control module will remote start Default 1 Will start every 3 hours until the vehicle is remote started or started by key and run for the set run time in option 1 08 Option 2 Will start every 1 5 hour...

Страница 16: ...llows the output duration to be set for a specific length of time 3 03 Aux 2 Output This option determines the duration of the Aux 2 output Setting 4 allows the output duration to be set for a specifi...

Страница 17: ...l settings Special Option Group 1 Change the timed output of Auxiliary 1 and 2 STEP 3 Hold the W Write button for 3 seconds This finalize option changes to the control module Wait until OP500 displays...

Страница 18: ...Tap Key Button Option Menu 2 Lock Unlock for 3 seconds then Lock Key for 3 seconds Hold Trunk Key for 3 seconds Tap Lock Button Tap Unlock Button Tap Key Button Option Menu 3 Lock Key for 3 seconds t...

Страница 19: ...signed to only work with 4 Pin antennas and compatible remotes It does not work with 6 to 6 Pin antennas I am trying to program options with the OP500 Option Programmer and it flashes ER 01 when I plu...

Страница 20: ...using a coil change to an injector or try alternator mode If you are using the tachless sensing mode and it does not start check the two power wire on the control module If it does not remote start y...

Страница 21: ...am 5 00 pm Pacific Standard Time Email support compustar com Web techfeed compustar com Wiring Diagrams Go to www firstechonline com to access Computech3 If you are an authorized dealer and unable to...

Отзывы: