background image

 

14

 

 

The  motor  unit  may  be  dismantled  from  the  pump  body  without  needing  to 
disconnect the pump’s suction and impulsion tubing. 

 

 

To disconnect the motor unit from the pump body, take out the screws that join them. 

 

 

 

 

 

 

 

 

 

 

 

 

POSSIBLE BREAKDOWNS, CAUSES AND SOLUTIONS 

 

Содержание POWERSTORM SERIES

Страница 1: ...assembling and starting up 1 GENERAL SAFETY INSTRUCTIONS These symbols represent the possibility of danger as a result of not following the corresponding instructions DANGER Electrocution risk Non co...

Страница 2: ...stallation should be carried out in accordance with the specific indications for each step The regulations in force for the prevention of accidents should be heeded Any modification that may be made t...

Страница 3: ...ied out by qualified and authorised people who have previously carefully read the installation and service instructions The operating safety of the machine is only guaranteed with the compliance and r...

Страница 4: ...lectrical installation should have a differential the value of which is not greater than 30mA Check that the terminal box joint is used correctly thus preventing water from entering the terminal box o...

Страница 5: ...BLY AND MAINTENANCE WORK WARNINGS National installation regulations should be taken into account when assembling and installing the pumps Special attention should be paid to ensure that under no circu...

Страница 6: ...pped completely The mentioned list should be considered indicative and not binding since there may be specific safety rules within specific safety procedures Periodically control The mechanical parts...

Страница 7: ...manufacturer 3 INSTALLATION AND ASSEMBLY GENERAL Assembly and installation of our pumps is only permitted in swimming pools or tanks complying with regulation HD 384 7 702 In case of doubt please con...

Страница 8: ...ct to the nozzle to be connected so as to avoid external pressure being exerted on the pump and the tube Apart from making assembly more difficult this pressure could even break them Fig 2 Suction tub...

Страница 9: ...d have a multiple separation system with contact opening of at least 3 mm Connection to the mains can only be done using a rigid cable In the event that a flexible cable is used this should have termi...

Страница 10: ...ative since the motor comes with an incorporated protector HEAT PROTECTOR TABLE P2 Mod Pump Code HP kW V Intensity relay regulation A 1 Powerstorm 500 0 5 0 409 240 3 24 2 Powerstorm 750 0 75 0 556 24...

Страница 11: ...ept any responsibility and considers the guarantee void Special installation regulations may exist The main cable can only be connected by qualified and authorised personnel Incorrect mains connection...

Страница 12: ...on the pre filter and screw it closed without forgetting to place the joint in its housing Fig 5 Under no circumstances should pumps work without previously having filled the pre filter with water If...

Страница 13: ...omer Technical Service If the amp rate is higher consult the manufacturer Empty the pump in cases where it must remain without use for some time mainly in cold countries where there may be danger of f...

Страница 14: ...dismantled from the pump body without needing to disconnect the pump s suction and impulsion tubing To disconnect the motor unit from the pump body take out the screws that join them POSSIBLE BREAKDO...

Страница 15: ...PUMP GIVES Motor turning direction incorrect III Invert two phases of the feeding line LOW FLOW VOLUME Load loss in suction Prevent as much as possible elements that produce load loss Wrong voltage Ch...

Страница 16: ...d damaging the pump s hydraulic parts The motors supplied with the motor pump unit have been protected by IP 55 and are prepared to withstand hot atmospheres and high humidity levels The motors are al...

Страница 17: ...17 The motor pump unit s functional characteristics are given in the different characteristic curves...