Страница 1: ...Model CEI 4730 ...

Страница 2: ...5 6 7 13 Individual Screen Detail Review Shot String Par Time Start Delay Type Backlight ON time Start Signal LED Beeper Headset Volume Home Screen Type Shot Dead Time Shot Sensitivity Date and Time Hit Factor Scoring Clear Data Review Previous string Battery Status info and warning screens Memory Info Resetting to Factory Defaults Specifications Warranty 7 8 8 9 9 9 9 10 11 11 11 12 13 13 13 14 1...

Страница 3: ...ot timer We are here to help if you have any questions or comments please contact us at 815 874 8001 or www competitionelectronics com The ProTimer is designed and built in the USA With proper use and care it will give you many years of trouble free service Thank you for purchasing our product ...

Страница 4: ...ttery in the compartment on the rear of the unit Once installed the ProTimer will briefly display a sign on message followed by the home screen Note If at any time you suspect the unit is not functioning properly try resetting it see page 14 To turn the unit ON press the SET DECR ON button After 10 minutes of inactivity the ProTimer will turn off automatically You may also turn it OFF by pressing ...

Страница 5: ...creen is the default style which shows the time to last shot time to the first shot current split time shot number and date time Note You can choose from two other screen configurations as shown on page 10 5 82SPL 1 00 1st 0 78 SHOT 5 3 30PM ...

Страница 6: ...ated MENU BUTTONS Marked on the front of the unit FWD and REV these buttons navigate back and forth through the continuous menu loop From the HOME screen the FWD button will advance to the more commonly used features and the REV button will advance to the less common features Once you become familiar with the MENU navigation you will learn which direction is the fastest route to find a particular ...

Страница 7: ...settable range you can hold down the button to automatically advance the digits and press both SET buttons simultaneously to clear the setting 4 LED Beeper Alerts The ProTimer has two indicators for signaling an event They are both active with the default settings but can be turned off if desired within the menu settings FWD INCR REV OFF DECR ON MENU SET PRO TIMER ...

Страница 8: ...ome screen and begin a new string 5 Headset Jack A standard 3 5mm stereo headset jack is located on the side of the unit The Piezo beeper is disabled when a headset is connected for a private practice session The beeper volume control will also change the headset volume level Shot Detection Each time a shot is detected it will be added to the shot string The timer will automatically calculate the ...

Страница 9: ...ht duration Start signal LED enable disable the start LED Beeper volume adjust headset and beeper volume Home screen type select from three configurations Shot dead time used for echo control indoors Shot sensitivity increase or decrease the shot sensitivity Date setting for review direct screen and time stamp of shot strings Time setting for review direct screen and time stamp of shot strings Hit...

Страница 10: ...nd finally the split time When navigating to the review shot screen after the completion of an event the first shot will appear on the 3rd line and the last shot will appear on the 2nd line if there are 4 or more shots in the string This is intended for the user to quickly locate the first and last shot information without keystrokes Use the SET INCR DECR buttons to scroll through the shot string ...

Страница 11: ...of par times 2 through 5 will string the beeps together in order When a value of zero is set in any of the par time locations it will halt any subsequent values from being active Par time is adjustable from 0 to 199 9 seconds Start Delay Type The start delay can be configured for instant fixed or a random value based on a minimum maximum time frame from the start beep INSTANT The default setting o...

Страница 12: ...nt of the unit can be enabled disabled by pressing one of the SET buttons This feature is intended for use when hearing the beeper is difficult but could also be considered as an alternative method for beginning a stage Beeper Headset Volume The volume control for beeper and headset volume can be adjusted from OFF to maximum with 10 levels Home Screen Type There are 3 home screen configurations to...

Страница 13: ...s and the time between the first and the last shot Shots recorded more than 199 99 seconds after the start beep will render readings invalid until the unit is restarted The ProTimer can detect shots at rates up to 1800 RPM 10 REVIEW DIRECT DEFAULT HOME SCREEN This selection is the default setting which shows more information with the penalty of a smaller time to the last shot The time to the first...

Страница 14: ...shots is less than 11 seconds an adjustment will be necessary Shot Sensitivity The sensitivity adjustment range is from 0 lowest to 25 highest The default setting of 13 will work with most types of firearms With the high range settings keep in mind that there may be false shot detection from handling or other noise sources Date and Time Settings for the date and time are entered on two screens and...

Страница 15: ...ge to record the time to the last shot then enter values for TOTAL STAGE POINTS and POINTS DOWN on the Hit Factor Scoring screen The score will automatically be calculated on the top line of the display You can adjust the time to the last shot value in order to see how the score is affected by a different amount of time ...

Страница 16: ...ew battery is not readily available A low battery critical warning message will appear when the unit is powered ON and the battery is too low for operation The unit will shut down and a new battery will be necessary for continued use Review Previous String Previous strings of fire can be recalled for review by selecting one of the flashing numbered values on the Review Previous String screen The c...

Страница 17: ...800 days A lithium battery has a typical rating of 750mA Under normal use a lithium battery will provide approximately 30 hours of service and an alkaline battery will provide approximately 25 hours of service 14 Memory info The ProTimer will retain up to 50 shot strings with up to 70 shots per string and all settable values in non volatile memory except date and time This means that they will not...

Страница 18: ...ds per Minute 1800 Max of Par Time Beeps 5 Start Delay Range 1 to 9 90 seconds Backlight On Time Range 0 99 seconds Beeper Output 1 5 Khz 100dB 200 msec duration LED Output 850 mcd 200 msec duration Max Time Limit 199 9 seconds before wraparound Average Battery Life 25 hours of operation Power Consumption See page 14 Battery Type 9 volt alkaline or lithium 15 ...

Страница 19: ... IMPLIED WARRANTIES INCLUDING MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE EXCLUDED ANY IMPLIED WARRANTIES NOT EXCLUDED ARE LIMITED IN DURATION TO 2 YEARS FROM DATE OF PURCHASE INCIDENTAL AND CONSEQUENTIAL DAMAGES ARE EXPRESSLY EXCLUDED FROM THE REMEDIES AVAILABLE TO THE PURCHASER AND THE REMEDIES PROVIDED IN THIS WARRANTY SHALL BE EXCLUSIVE TO THE EXTENT PERMITTED BY LAW Note Some state...