USER MANUAL
uSign™
Signature Capture Module
Models uSign 100 & uSign 200
80084501-001-A 04-24-2007
Страница 1: ...USER MANUAL uSign Signature Capture Module Models uSign 100 uSign 200 80084501 001 A 04 24 2007...
Страница 2: ...us does not exceed the Class B limits for radio noise for digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n m...
Страница 3: ...imited warranty service during the warranty period please contact ID TECH to obtain a Return Material Authorization RMA number instructions for returning the product THIS WARRANTY IS IN LIEU OF ALL OT...
Страница 4: ...version 13 7 2 2 Get serial number 13 7 2 3 Get clip area 13 7 2 4 Set clip area 13 7 2 5 Clear clip area 13 7 3 One byte commands 14 7 3 1 Stop Capturing 14 7 3 2 Start Capturing use FBP format 1 14...
Страница 5: ...3 Clear display screen 16 7 4 14 Draw line 16 7 4 15 Draw hollow rectangle 16 7 4 16 Draw solid rectangle 16 7 4 17 Draw text 16 Table of Figures Figure 1 New Hardware Wizard opening window 9 Figure 2...
Страница 6: ...g replacement if the signature area becomes worn from stylus use Customer specific front overlay designs are possible as needed by an application There are two major uSign housing configurations The f...
Страница 7: ...with a 9VDC power adaptor The uSign 200 with an RS232 interface uses a standard DB9 connector and uses a 5VDC power adaptor The input voltage on the power adaptors may be limited do not exceed the inp...
Страница 8: ...vice Pack 1 can cause intermittent problems use Service Pack 2 Connect the USB connector to the PC and insure it is fully seated into the jack If the LEDs do not light check the connections and the av...
Страница 9: ...pening window Browse and select the folder where the uSignUsbCDC inf and companion usbser sys files are located Click Next to continue Figure 2 Browse for File Copyright 2006 International Technologie...
Страница 10: ...l Panel and follow the selections System Hardware Tab and Device Manager Expand the Port COM LPT folder There should be an item IDTECH USB RS232 uSign COM where is a Port number uSign is set up and co...
Страница 11: ...ud rates 1200 to 115200 Default 9600 baud data bits 8 Parity none Stop bit 1 USB 2 0 Full Speed Common Device Class 6 6 LED Two individual LEDs one green one red Signature Pad or Host controlled 6 7 A...
Страница 12: ...uSign User Manual 10 to 95 non condensing Copyright 2006 International Technologies Systems Corp All rights reserved Page 12 of 18...
Страница 13: ...in response string Several bytes needed Lrc1 Exclusive or of ResponseData 1 byte Lrc2 Sum of ResponseData 1 byte ETX 0x03 1 byte 7 2 System Commands 7 2 1 Get firmware version Command string 78 01 Res...
Страница 14: ...string C4 Response string C4 7 3 6 Clear CMP format mode data Command string C5 Response string C5 7 3 7 Get data 0x00 Command string C6 or D4 or D5 Response string 00 7 3 8 Start Capturing use CMP f...
Страница 15: ...Response string 01 7 4 5 Set interval between two points Command string 28 15 01 00 xx Response string 01 7 4 6 Get data 0x00 0x01 Command string 2A 15 00 00 Response string 00 01 7 4 7 Calibrate the...
Страница 16: ...se string Line is defined by two points x1 y1 x2 y2 7 4 15 Draw hollow rectangle Command string 50 32 08 00 Left 2 bytes Top 2 bytes Right 2 bytes Bottom 2 bytes Response string 7 4 16 Draw solid rect...
Страница 17: ...uSign User Manual uSign 100 SIGNATURE CAPTURE PAD Figure 4 Outline Drawing for uSign 100 Copyright 2006 International Technologies Systems Corp All rights reserved Page 17 of 18...
Страница 18: ...uSign User Manual uSign 200 SIGNATURE CAPTURE PAD Figure 5 Outline Drawing for uSign 200 Copyright 2006 International Technologies Systems Corp All rights reserved Page 18 of 18...