Connectors, LED Indicators, Switches, and Jumpers
NAS B2000 Maintenance and Service Guide
4-15
COMPAQ CONFIDENTIAL
Codename: Collins Part Number: 292280-001 Last Saved On: 5/30/02 1:06 PM
10
11
3
4
5
6
7
8
9
2
1
12
Figure 4-12: System board LEDs
Table 4-8: System Board LEDs
Item
LED Description
Status
Processor 1 failure
Processor 2 failure
Amber = Processor failed
Off = Normal
DIMM failure 6C
DIMM failure 5B
DIMM failure 4A
DIMM failure 3C
DIMM failure 2B
DIMM failure 1A
Amber = Memory failed
Off = Normal
PPM 2 failure
Amber = PPM failed
Off = Normal
Overtemperature
Amber = Temperature has exceeded OS cautionary
level or critical hardware level.
Off = Temperature is OK.
PPM 1 failure
Amber = PPM failed
Off = Normal
Riser/SCSI interlock failure
Amber = PCI Riser or Smart Array 5i controller not
seated
Off = Normal
Note:
When the SCSI interlock disable switch is set to default (off), the riser/SCSI interlock failure
LED indicates that the PCI riser or the Smart Array 5i Controller is unseated. If the default setting is