Compaq StorageWorks 4000 - RAID Array Скачать руководство пользователя страница 1

To install the Compaq StorageWorks RAID Array 4000 redundant
components, you will need to perform the following procedures:

1.

Shut down the server and the storage system.

2.

Install the RA4000 Redundant Controller
by completing these steps:
A. Remove the blank panel located at the rear of the

RA4000.

B. Insert the RA4000 Redundant Controller into the

tracks in the rear panel opening.

C. Push the board in as far as it will go and close both

latches against the rear panel. The levers on each
latch should catch behind the metal lip, drawing the

        board into position and securing it into place.

3.

Install the second Compaq Fibre Channel Storage Hub in the
rack or other location. Refer to the documentation supplied
with this device for details.

4.

Install the second Compaq Fibre Channel Host Adapter
in a convenient slot in the server. Refer to the Compaq
StorageWorks Fibre Channel Host Adapter Installation Guide
.

5.

Install the GigaBit Interface Converter (GBIC) modules in
the receptacles provided on the Fibre Channel host adapter,
RA4000 Controllers, and Fibre Channel Hubs.

Simplified Instructions for Installing the Redundant Components

©1999 Compaq Computer Corporation.

All rights reserved. Printed in the U.S.A.

Compaq, ProLiant, ProSignia, and ROMpaq

registered United States Patent and Trademark Office.

First Edition (June 1999)

Part Number 340426-001

340426- 001

Ref #

Identifier

1

RA4000 Controller

2

RA4000 Array

3

GigaBit Interface Converters

4

Fibre Channel Host Adapters

5

Fibre Channel Storage Hub 7 or 12

6

Server

StorageWorks RAID Array 4000

6.

Connect the Fibre Channel host adapter, the RA4000
Controller, and the Storage Hub, using the appropriate
length of multi-mode Fibre Channel cable. Two GBIC
modules are required for each Fibre channel cable installed.

7.

Apply power to the equipment in the following order:

A. Storage Hubs (accomplished by plugging in A/C

power cord)

B. RA4000
C. Server

Features

The following features apply to the Compaq StorageWorks RAID Array
4000:

Models

Rack-Mountable or Tower

Maximum Number of Drives

Twelve, 1-inch
Eight, 1.6-inch

Hard Drive Interface

Wide-Ultra SCSI-3
Fast-Wide SCSI-2

SCSI ID Select

Automatic

Hubs

Storage Hub 7
Storage Hub 12

GBICs

GBIC-SW, GBIC-LW

Fibre Channel Cable Types

50-micron multimode
62.5-micron multimode
9-micron single mode

Option

Redundant Power Supply

Hot-Pluggable Components

Hard Drives
Fan Assembly
Redundant Power Supplies
Fibre Channel Host Adapters
RA4000 Controllers
Fibre Channel Cable

Status Indicators

Storage System Front Panel
Fan Assembly RA4000 Controller

StorageWorks RAID Array 4000 Features

6

1

2

1

2

3

4

5

3

3