Configuring the GbE Interconnect Switch Using the Web-Based Management Interface
Compaq ProLiant BL p-Class GbE Interconnect Switch User Guide
4-35
COMPAQ CONFIDENTIAL
Codename: Vanilla Part Number: 263680-001 Last Saved On: 4/23/02 10:02 AM
Configuring the Trap Manager
When you select
Trap Manager
from the
Management
menu, the following screen is
displayed.
The
SNMP Trap Manager Configuration
window allows you to set the trap receiving
station, which runs a network management application to receive and store traps.
You can change the following parameters:
•
Trap Receiving Station
—Type the IP address of the trap receiving station.
•
Community String
—Type a user-defined SNMP community name.
•
Status
—Set the trap receiving station status to
Valid
or
Invalid.
Click
Apply
after making changes to the settings.
NOTE:
To save the configuration settings permanently, you must enter them into NVRAM using the
Save Changes
option on the
Maintenance
menu. Refer to the section, “Saving Changes,” earlier in
this chapter.
Setting Up and Managing User Accounts
When you select
User Accounts
from the
Management
menu, the following screen is
displayed.
The
User Account Management
window displays all current users for the GbE Interconnect
Switch and their current access level.
The following information is displayed:
•
User Name
—Displays all current users for the GbE Interconnect Switch.