4. Adjustment
4-1 Adjustment Conditions And Precautions
1.
Approximately 30 minutes should be allowed for warm up before proceeding.
2. Adjustments should be undertaken only on those necessary elements since most of them have been
carefully preset at the factory.
4-2 Main Adjustments
No. Function
Location
Designation
1
B + ADJ
PCB - MAIN
VR902
2
SCREEN ADJ
FLY BACK TRANS
T402
3
FOCUS ADJ
FLY BACK TRANS
T402
4
ABL ADJ
FACTORY OSD
ABL FUNCTION
- SELECT
PCB - MAIN
<SW101>
- DOWN (-)
PCB - MAIN
<SW102>
- UP (+)
PCB - MAIN
<SW103>
5 FUNCTION
ADJ
- MENU
PCB - MAIN
<SW104>
4-3 Adjustment Method
1. B + & HV voltage adjustment:
A. Chroma-2000 Signal generator or PC equivalent set mode 1, VGA 640X480 pattern 1.0 .
B. Connect a DC Volt meter between D925 cathode and ground, then adjust VR902 to be 66.0 VDC for
CPT CRT or LPD CRT.
2. Factory preset Timings Adjustment:
A. Press MENU Key to show OSD window press Up or Down Key to switch the functional controls.
B. Press the Up Key to select the "MORIE" function, then press the SELECT Key. While do not release the
SELECT Key until the OSD window changed to the Factory preset window.
C. The Factory preset window contains the following functional controls. Select one of the control. Then
press the Up/Down Key to adjust its value for the optimum picture.
(The OSD menu for factory preset FOR WT CPU)
Содержание MV7540
Страница 21: ...HP MV7540 21 7 Mechanical Of Cabinet Front Dis Assembly...
Страница 38: ...HP MV7540 38 9 Block Diagram...
Страница 39: ...HP MV7540 39...
Страница 40: ...HP MV7540 40 10 IC Block Diagram...
Страница 41: ...HP MV7540 41...
Страница 42: ...HP MV7540 42...
Страница 43: ...HP MV7540 43...
Страница 44: ...HP MV7540 44 11 PCB Layout...
Страница 45: ...HP MV7540 45...
Страница 46: ...HP MV7540 46 12 SCHEMATIC DIAGRA...
Страница 47: ...HP MV7540 47...
Страница 48: ...HP MV7540 48...
Страница 49: ...HP MV7540 49...