Observe the warnings and cautions provided in the option kit documentation
and in this guide. To install the processor and heatsink assembly:
1. Verify that all critical data has been backed up.
2. Ensure that your server has the most current ROM version. To update
your ROM, see the following website:
www.compaq.com/support/files/
3. Power down the server and remove the access panel as described in the
section applicable to your tower or rack server earlier in this chapter.
4. To gain access to the processor sockets, remove the internal fan baffle.
See “Removing the Fan Baffle” earlier in this chapter.
5. Locate the processor socket and corresponding PPM slot on the system
board.
1
2
3
4
Figure 3-28. Locating the processor sockets and Processor Power Module
(PPM) slots