Compaq ProLiant BL20p Server Blade Maintenance and Service Guide
2-1
COMPAQ CONFIDENTIAL
Codename: AvalancheX Part Number: 316080-001 Last Saved On: 12/18/02 11:31 AM
2
Removal and Replacement Procedures
This chapter provides subassembly/module-level removal and replacement procedures for
system components. After completing all necessary removal and replacement procedures,
verify that all components operate properly by running the appropriate diagnostic software:
•
For server blade components, run the Compaq Server Diagnostics utility, available from
the Compaq website:
www.compaq.com
•
For server blade enclosure and power enclosure components, run the infrastructure
diagnostics. Refer to Chapter 3, “Diagnostic Tools,” for more information.
Safety Considerations
Electrostatic Discharge Information
A discharge of static electricity can damage static-sensitive devices or microcircuitry. Proper
packaging and grounding techniques are necessary precautions to prevent damage. To
prevent electrostatic damage, observe the following precautions:
•
Transport products in static-safe containers such as conductive tubes, bags, or boxes.
•
Keep electrostatic-sensitive parts in their containers until they arrive at static-free
stations.
•
Cover workstations with approved static-dissipating material. Use a wrist strap connected
to the work surface and properly grounded tools and equipment.
•
Keep the work area free of nonconductive materials such as ordinary plastic assembly
aids and foam packing.
•
Always be properly grounded when touching a static-sensitive component or assembly.
•
Use conductive field service tools.
Server Blade Warnings and Cautions
WARNING: To reduce the risk of shock or injury from high current electrical energy, do
not remove the server blade access panel while the server blade is installed in the
server blade enclosure. Do not remove the server blade access panel and then install
the server blade into the server blade enclosure.