Troubleshooting
Table D-5: Is the Enclosure Health LED on the Front of the Enclosure On?
Answer Possible
Reasons Possible
Solutions
The enclosure status cable is
disconnected from the center wall
assembly or the enclosure status
assembly.
Securely attach the enclosure status
cable.
No, it is off.
The enclosure status assembly or the
center wall assembly is not
functioning properly.
Contact HP or an authorized service
provider for parts and service.
Check the local or remote console for
error messages. Go to table D-6.
Check system fans. Go to Table D-8.
Yes, it is
amber.
A system component is degraded, but
the system is still functional.
Contact HP or an authorized service
provider for parts and service.
Check the local or remote console for
error messages. Go to table D-6.
Check system fans. Go to Table D-8.
Yes, it is red.
A system component has a critical
failure.
Contact HP or an authorized service
provider for parts and service.
Check the local or remote console for
error messages. Go to table D-6.
Yes, it is
green.
The Integrated Administrator has not
detected any degraded or failed
components.
Contact HP or an authorized service
provider for parts and service.