Guide:
SYSTIMAX
®
iPatch
®
Panel Manager Guide
2–18
7
Program the gateway:
a
Press
Ê
until the display shows:
b
With Gateway highlighted, press Select.
The display shows:
c
Enter the gateway provided by your data network administrator.
To change a digit, press
_
or
`
until the desired digit is highlighted. Then
press
Ç
and
Ê
until the desired number appears.
d
Press Save.
The Panel Manager sounds a completion tone.
Note:
The Socket setting is the address the Panel Manager
uses to communicate
with System Manager. Do not change this address unless your computer network
administrator instructs you to do so.
8
Confirm the Ethernet speed setting matches the setting provided by your
network administrator by pressing
Ê
until the display shows:
To change the Ethernet speed setting:
a
With Speed highlighted, press Select.
The display shows:
b
Press
Ç
or
Ê
to highlight the desired setting.
c
Press Save.
The Panel Manager sounds a completion tone.
Network: Ethernet
Network Manager LAN: Disabled
IP Address: 135.005.126.237
Subnet Mask: 255.255.255.000
Gateway: 000.000.000.000
Socket: 08510
Select Restore Defaults Exit
Network: Ethernet
Network Manager LAN: Disabled
IP Address: 135.005.126.237
Subnet Mask: 255.255.255.000
Gateway: 0
00.000.000.000
Socket: 08510
Enter each digit. Then press Save.
Save Cancel
Network Manager LAN: Disabled
IP Address: 135.005.126.237
Subnet Mask: 255.255.255.000
Gateway: 000.000.000.000
Socket: 08510
Speed: 100 MB/sec
Select Restore Defaults Exit
Speed: 10 MB/sec
100 MB/sec
Auto-negotiate
Highlight a setting. Then press Save.
Save Cancel