background image

860547876 
imVision

®

 Controller User Guide 

 

www.commscope.com 

 

Page 8 of 15 

In addition to the display information, LEDs  above the relevant ports will indicate where  to add or remove the 
connection for the given  job.  Completing  each  patching  job automatically queues the next job on the list to be 
performed.

 

If  a  job  requires  adding  or  removing  a  connection  between  an  iPatch  panel  and  non-iPatch equipment, the 
display and the correct LED on the panel will indicate where to add/remove the patch on the iPatch Panel. The 
display will also identify the

 

non-iPatch equipment. When working with non-iPatch connections, be sure to press 

and hold the button above the corresponding iPatch port on the iPatch Panel for 2 seconds. This will confirm that 
the job has been completed. Completing this activity automatically queues the next job on the list to be performed.

 

Performing Unguided Patching Jobs 

To add or remove connections not in the  Jobs list, simply connect each end of the patch cord to the appropriate 
ports on the  iPatch  Panel.  If  you  are  making  a  Simplex connection in duplex ports, connect both  ends of  the 
patch cord. Then tap 

Simplex

 on the touchscreen display. 

To add a connection between an iPatch Panel and non-iPatch equipment, first plug in the non-iPatch equipment, 
then plug the other end of the patch cord into the iPatch panel. Press and hold the button above the newly occupied 
port on the iPatch Panel for 2 seconds. This will confirm that the unguided equipment patch has been completed. 
Another method is pressing the 

Equipment

 button to complete connections to non-iPatch equipment. 

To disconnect non-iPatch equipment from the  iPatch  Panel,  unplug  the  patch  cord  from  the  equipment.  Then, 
disconnect the patch cord from the panel. Press and hold the button above the newly vacated port on the iPatch 
Panel for 2 seconds. This will confirm that the unguided equipment patch removal has been completed. 

Tracing a Patch Connection 

When you connect a patch cord to an iPatch Panel, the system records the connection in a database. To trace 
the connection, simply press the button above one of the ports used for the connection. The panel indicates each 
end of the connection by lighting a LED above each of the ports. Also, the display of the imVision Controller lists 
the ports used in the connection. To learn more, tap the port information on the display and you can see details 
on any devices in this connection. To end the trace, press the button above one of the ports. 
If only one of the ports in a patch connection is on an iPatch Panel, you still can trace the connection. The LED 
turns on above the iPatch Panel port. The imVision Controller display shows as much information as is known 
about the connection. If the connection was made as a guided job, both the iPatch Panel port and the equipment 
port are identified. 

Correcting Patching Errors 

If you discover that a patch cord is connected to the wrong port or that the database has recorded a connection 
that does not exist between two ports, you can correct the database using the Change feature.  

To correct a connection, please use the following steps. 

Step 1 

– Show a circuit trace 

 

The first step in correcting a patching error is to show a 
circuit trace for a targeted port. To show a circuit trace, 
press the panel button corresponding to an iPatch Panel 
port. The LEDs associated with connected iPatch Panel 
ports will turn on. On the display, a graphical circuit trace 
will be shown, along with a Change button. 
 

 

Содержание SYSTIMAX imVision

Страница 1: ... Instructions 2 The imVision System 3 iPatch Panel 3 imVision Controller 3 Ordering Panels in the imVision System 4 Following Prompts in the imVision System 5 Screen Lock PIN Feature 5 Audible and Visible Feedback 6 imVision System Manager Software 6 Settings 7 Patching Mode 7 Patching and Tracing 7 Performing Guided Patching Jobs 7 Performing Unguided Patching Jobs 8 Tracing a Patch Connection 8 ...

Страница 2: ... product on an unstable cart stand or table The product may fall causing serious damage to the product When installing iPatch equipment not described in this guide follow the instructions provided with that equipment Take care not to compromise the stability of the rack by installation of equipment The touchscreen display is designed to be used without the need for a stylus Never use sharp objects...

Страница 3: ... sensor changes at the iPatch panels By monitoring button presses and sensor changes at the panels the imVision Controller logically infers when patch connections are added or deleted and updates the database accordingly In most configurations multiple imVision Controller units are grouped and connected into patching zones Each patching zone requires a LAN connection in order to communicate with t...

Страница 4: ... the rack and so on Press each button to hear a tone confirming its inclusion in the order until all the panels in the rack are numbered At that point the tone will change and the imVision System will enter the Ready state with the Home screen appearing on the interface If the rack includes a high density fiber shelf or shelves you must also order the modules by pressing a button on each module of...

Страница 5: ...y Screen Lock PIN Feature When enabled the Screen Lock PIN feature locks an imVision Controller display until a PIN is entered on the display number keypad Touch the lock icon on the bottom right corner of display to show a keypad then enter PIN to unlock the display screen Enable the screen lock PIN feature by entering the Controller Settings menu on the Home screen Choose Screen Lock Settings ch...

Страница 6: ...ort beep Pressed controller key Inserted or removed a patch cord at an iPatch Panel Completion tone 3 short tones low medium high Added or removed patch connection at an iPatch Panel Indicated the position of a row of iPatch Panel ports Saved a network setting Confirmation tone 2 short tones Programmed the order of the panels and modules in the rack Attention tone 1 long low tone Technician is req...

Страница 7: ...ormal the imVision Controller shows the patching mode on the Idle screen below the Rack Name The patching mode is set to Normal when the Jobs button is pressed Normal All imVision Controllers in this mode monitor connections simultaneously for a given Controller LAN Local Unless the Jobs button is pressed each imVision Controller monitors only the activity in its own rack creating a local patching...

Страница 8: ...m the iPatch Panel unplug the patch cord from the equipment Then disconnect the patch cord from the panel Press and hold the button above the newly vacated port on the iPatch Panel for 2 seconds This will confirm that the unguided equipment patch removal has been completed Tracing a Patch Connection When you connect a patch cord to an iPatch Panel the system records the connection in a database To...

Страница 9: ...ced port Step 3 Confirm the correct connection for each port After using the Change button the imVision Controller will automatically step through each port that was involved in the changed connection For each port a Confirm screen will appear to provide guidance for confirming the connection information Follow the on screen instructions to create a new connection relationship between ports or wit...

Страница 10: ...t the patch connection you want to confirm Then either Press and hold the port button in the panel directly above the port where the other end of the cord is inserted and confirm on the display that the connection is complete or If the other end of the patch cord is hanging free plug in the cord and answer Yes to the question Insert one end of the patch cord and press and hold the button on the pa...

Страница 11: ...ther the B or A strand is the far end of the patch being confirmed When the correct connection is displayed press Yes Complete the connection to equipment Press and hold the iPatch panel port s button for 2 seconds or press the Equipment button on the imVision Controller display Remove the connection Remove both ends of the patch cord Connecting Controllers in a Zone A zone is a group of racks and...

Страница 12: ...ed if the port is used to connect from the imVision Controller to another controller in the zone The Controller mode is selected when the button next to a port is in the pushed out position When pushed out the button is flush with the controller housing The example above shows the patch cord connections and button positions required to configure a zone containing three imVision Controllers ...

Страница 13: ...rder ofiPatch equipment in the rack You attempt to trace a patch connection and the LEDs do not turn on where you expect a Patch cord is not connected where it is supposed to be b Wrong connection has been recorded in the database a Manually trace the patch connection to determine the other end of the connection Remove the patch cord and reconnect the patch cord to the proper ports b Use the Trace...

Страница 14: ...roperly for the current patching b imVision Controller is not connected to the adjacent imVision controller c imVision Controller has failed d imVision Controller is not responding e Panel or module is not communicating with the imVisionController f Patch cord connecting an imVision Controller to an adjacent controller failed a At each imVision controller press Home to view the controller configur...

Страница 15: ... a The Controller in question has lost power b The Controller in question is improperly connected to the other controllers in the patching zone c The Controller in question does not have its IN and OUT port switches configured correctly d The Controller has been removed from the patching zone in question e The Controller in question has failed a Make sure the Controller is properly connected to it...