![CommScope RUCKUS ICX 7550 Скачать руководство пользователя страница 120](http://html1.mh-extra.com/html/commscope/ruckus-icx-7550/ruckus-icx-7550_hardware-installation-manual_2643845120.webp)
Model Name (Input
Power +/-5%)
@100 VAC Input
@200 VAC Input
@-48 VDC Input
Minimum Number of
Power Supplies
Notes
ICX 7550-48ZP
1183.7 W
4036.42 BTU /hr
1315.8 W
4486.88 BTU/hr
N/A
1 x 1200 W AC
1 PSU
2159.8 W
7364.92 BTU/hr
2373.9 W
8095 BTU/hr
N/A
2 x 1200 W AC
2 PSUs required for PoE
loading
ICX 7550-24F
142.7 W
486.6 BTU/hr
142 W
484.22 BTU/hr
147.96 W
504.55 BTU/hr
1 x 400W AC or 1 x
400W DC
1 PSU
156 W
531.96 BTU/hr
156.4 W
533.32 BTU/hr
161.89 W
552.06 BTU/hr
2 x 400W AC or 2 x
400W DC
2 PSUs
ICX 7550-48F
166.8 W
568.78 BTU/hr
166.0 W
566.06 BTU/hr
168.07 W
573.12 BTU/hr
1 x 400W AC or 1 x
400W DC
1 PSU
178.6 W
609.03 BTU/hr
177.7 W
605.96 BTU/hr
181.52 W
618.98 BTU/hr
2 x 400W AC or 2 x400W
DC
2 PSUs
Power Consumption (Modules)
NOTE
The module names were inherited from the ICX7650.
Name
Description
Power Consumption
ICX7650-4X10GF
4-port 1/10 GbE SFP+ expansion module
Typical = 12.96 W
Maximum = 15.72 W
ICX7650-2X40GQ
2-port 40 GbE QSFP+ data uplink/stacking module
Typical = 5.64 W
Maximum = 7.38 W
ICX7650-1X100GQ
1-port 100 GbE QSFP28 data uplink/stacking module
Typical = 5.64 W
Maximum = 7.38 W
ICX-FAN12-E
Power-supply-side for exhaust airflow fan assembly
Typical = 4.68 W
Maximum = 16.68 W
ICX-FAN12-I
Power-supply-side for intake airflow fan assembly
Typical = 4.68 W
Maximum = 16.68 W
Data Port Specifications (Ethernet)
NOTE
The pluggable-module names listed below were inherited from the ICX7650.
Model
Port Type
Number of Ports (in
Module)
Description
ICX 7550-24
40 GbE
2 (slot 2)
QSFP+ stacking ports, 40 Gbps, compatible with optical transceivers, or
direct attached copper cable
1 GbE
24 (slot 1)
10/100 Mbps/1 GbE RJ-45 ports
RUCKUS ICX 7550 Switch Technical Specifications
Power Consumption (Modules)
RUCKUS ICX 7550 Switch Hardware Installation Guide
120
Part Number: 53-1005648-04
Содержание RUCKUS ICX 7550
Страница 10: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 10 Part Number 53 1005648 04 ...
Страница 54: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 54 Part Number 53 1005648 04 ...
Страница 66: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 66 Part Number 53 1005648 04 ...
Страница 76: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 76 Part Number 53 1005648 04 ...
Страница 90: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 90 Part Number 53 1005648 04 ...
Страница 102: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 102 Part Number 53 1005648 04 ...