4-Post Equipment Rack Assembly Instructions 

 

 

 

 

© 2013 CommScope, Inc.  All rights reserved 

Page 1 of 5 

 

General 

The 4-post equipment racks are  industry standard 19-inch (483mm)  and 23-inch (584mm)  wide racks 
available in 7 foot (2.1m), 8 foot (2.4m), and 9 foot (2.7m)  heights with either aluminum or steel vertical 
uprights (rails).  Aluminum uprights include 12-24 tapped holes that accept 12-24 x 1/2” mounting screws 
(provided). Steel uprights include  punched holes that accept M6 cage nuts and M6 x 12 mm mounting 
screws (both provided).  The 4-post racks are designed to withstand a 2000 lb. (454 Kg) static load. 

Ordering information is provided below: 

Part Number 

Ordering No. 

Description 

RK4P45-29A 

760082529 

45U Rack, aluminum rails, 29” x 7’ (.7m x 2.1m) 

RK4P52-29A 

760082537 

52U Rack, aluminum rails, 29” x 8’ (.7m x 2.4m) 

RK4P45-36A 

760082560 

45U Rack, aluminum rails, 36” x 7’ (.9m x 2.1m) 

RK4P52-36A 

760082578 

52U Rack, aluminum rails, 36” x 8’ (.9m x 2.4m) 

RK4P58-36A 

760139709 

58U Rack, aluminum rails, 36” x 9’ (.9m x 2.7m) 

RK4P58-36A-23 

760142331 

58U Rack 23” (584mm) wide, aluminum rails, 36” x 9’ (.9m x 2.7m) 

RK4PE-45-29S 

760175703 

45U Rack, steel rails, 29” x 7’ (.7m x 2.1m) 

RK4PE-52-29S 

760175711 

52U Rack, steel rails, 29” x 8’ (.7m x 2.4m) 

RK4PE-45-36S 

760175729 

45U Rack, steel rails, 36” x 7’ (.9m x 2.1m) 

RK4PE-52-36S 

760175737 

52U Rack, steel rails, 36” x 8’ (.9m x 2.4m) 

How to Contact Us 

 

To find out more about 

CommScope

® 

 product

 

 

For technical assistance: 

Within the United States, contact your local  account representative or technical support at  

 Outside the United States, contact your local account representative or 

Authorized Business Partner. 

Within the United States, report any missing/damaged parts or any other issues to 
CommScope Customer Claims 

 Outside the United States, contact your 

local account representative or Authorized Business Partner. 

 

 

WARNING

 

Legal Disclaimer:

  It is highly recommended that installation of this  product  be performed by a qualified and experienced 

installer.    Improper installation of this product could result in damage to the product, other equipment, or personal injury.  

CommScope

  cannot be held responsible for  damage to equipment or personal injury resulting from improper fastening or 

misuse of information presented in this document.  

Racks must be wired per applicable sections of the National Electrical 

Code (NEC).  If grounding is required, appropriate grounding hardware approved by the NEC must be used. 

 

Содержание RK4P45-29A

Страница 1: ...ck steel rails 29 x 7 7m x 2 1m RK4PE 52 29S 760175711 52U Rack steel rails 29 x 8 7m x 2 4m RK4PE 45 36S 760175729 45U Rack steel rails 36 x 7 9m x 2 1m RK4PE 52 36S 760175737 52U Rack steel rails 36 x 8 9m x 2 4m How to Contact Us To find out more about CommScope product For technical assistance Within the United States contact your local account representative or technical support at Outside th...

Страница 2: ...ts 40 12 24 x 1 2 mounting screws 40 M6 x 12 mounting screws 40 M6 cage nuts 1 1 Instruction sheet Recommended torque for 12 24 and M6 screws is 30 in lb 3 4 N m Step 1 Assembly of Vertical Rack Rails 1 Lay two vertical rack rails on the floor with flanges facing each other 2 Position one extruded base angle and one extruded top angle on the vertical rack rails as shown in the following figure 3 I...

Страница 3: ...860421239 Issue 5 March 2013 Page 3 of 5 ...

Страница 4: ...Extruded base angles should face away from each other 2 Position the base pan near the extruded base angles and the upper support plate near the extruded top angles on the vertical rack rails 3 Attach upper support plate and base pan to assembled vertical rack rails as shown in figure on next page Insert twelve 3 8 x 1 hex head bolts 3 8 lock washers and 3 8 hex nuts Hand tighten only ...

Страница 5: ...ther non combustible surfaces 1 The equipment rack must be securely anchored to the floor or to an equally stabilized and secure surface using approved mounting hardware 2 The structural integrity of the rack will only be as good as the quality of the rack to floor attachment Using improper sized anchors or failing to secure all floor bolts can result in structural failure and possibly personnel i...

Отзывы: