![CommScope OneCell RP5100i Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/commscope/onecell-rp5100i/onecell-rp5100i_hardware-installation-and-commissioning_2643756083.webp)
Chapter 5
Configuring the OneCell system
OneCell
®
Installation and Commissioning, RP5000 series, Release 4.0
5-13
D
R
A
F
T
!
interface Vlan1
no ip address
shutdown
!
interface Vlan10
ip address 1.1.1.1 255.255.255.0
!
ip http server
ip http secure-server
!
access-list 100 permit udp any range 319 320 any
!
!
!
line con 0
password 7 10480E03514244
line vty 0 4
password 7 0820455C1F180B16
login
line vty 5 15
password 7 0820455C1F180B16
login
!
!
end
Accessing the Web GUI
The controller GUI is accessible over secure http. The application for the GUI listens
on port 6002. Use the controller GUI to configure components after initial hardware
installation, view status and statistics of the controller and its associated Radio Points.
The following browsers are supported by the Web GUI:
•
Mozilla Firefox
•
Google Chrome
•
Microsoft Internet Explorer
•
Microsoft Edge
•
Safari on Mac Only
Содержание OneCell RP5100i
Страница 7: ...Contents OneCell Installation and Commissioning RP5000 series Release 4 0 vii DRAFT ...
Страница 10: ...List of tables x 913035 4 0 04 June 2019 DRAFT ...
Страница 12: ...Document revision history xii 913035 4 0 04 June 2019 DRAFT ...
Страница 18: ...About this document xviii 913035 4 0 04 June 2019 DRAFT ...
Страница 20: ...DRAFT ...
Страница 28: ...DRAFT ...
Страница 42: ...Chapter 4 RP5100i installation 4 6 913035 4 0 04 June 2019 DRAFT 5 Replace the ceiling tile with the cutouts ...
Страница 68: ...Chapter 4 RP5100i installation 4 32 913035 4 0 04 June 2019 DRAFT Installation is complete ...
Страница 69: ...DRAFT Part III Commissioning Chapter 5 Configuring the OneCell system ...
Страница 70: ...DRAFT ...