4. Commissioning
Page 50
M0200AJA_ION-U_EU_L_17EP_17EP.docx
User’s Manual for ION
®
-U
Typical RS-232 connections for a system with up to two Remote Units and up to three
Extension Units are shown in the table below:
RS-232 LOCAL and CTRL Connections
Path 1 (RU 1)
Path 2 (RU 2)
RU 1 LOCAL
EU 1 CTRL Path 1
RU 2 LOCAL
EU 1 CTRL Path 2
EU 1 LOCAL Path 1
EU 2 CTRL Path 1
EU 1 LOCAL Path 2
EU 2 CTRL Path 2
EU 2 LOCAL Path 1
EU 3 CTRL Path 1
EU 2 LOCAL Path 2
EU 3 CTRL Path 2
EU 3 LOCAL Path 1
Not Connected
EU 3 LOCAL Path 2
Not Connected
table 4-7 RS-232 LOCAL and CTRL connections
4.3. Low Power EU Alarms
4.3.1. Bite and alarms
The Built-In Test concept comprises the monitoring of the power supplies and the
power amplifiers.
All alarms that occur can be checked via software at the Master Unit.