CommScope Era
™
High Power Carrier Access Point Installation Guide — Preliminary
M0201AKB_uc
Page 10
© January 2019 CommScope, Inc.
CAP H Overview
The “REF #” column in
refers to the callouts in
and
.
Table 3.
Function of the Connectors and Status LED Models with Two Antenna Connectors
REF # Label
Description
Function
1
A
RJ45 Auxiliary port
Connects to external Ethernet devices such as WiFi and IP cameras. Cabling is via the
appropriate CAT cable for the protocol; this model supports a 1000 BASE-T and 802.3at
Class 4 Power over Cat6A Ethernet connection. Maximum attached cable length is 3
meters (9.8 feet), per 802.3ATclass4 standards. For information on the Auxiliary port
in cascades, see
"CAP H Installation and Cascade Rules" on page 20
. The Auxiliary port
ships with factory-installed EMI/weatherproof plug, and must remain plugged if not in
use; graphic shows an OCTIS connector (PN 7760652) in black.
2
1
Optical Port 1
Can be one of the following:
• Connects to a Primary CAP H to a Classic CAN or TEN to provide the main signal
interface. Optical transport occurs over Single Mode Fiber (SMF) or Multi Mode
Fiber (MMF). Requires Optical OCTIS Kit (PN 7770612); Optical Port 1 ships with a
dust cap that can be discarded upon unit installation.
• Connects a Secondary CAP H to Optical Port 2 of the Primary CAP H.
3
2
Optical Port 2
Connects to an optional cascaded secondary CAP H via an Optical OCTIS Kit (PN
7770612). Optical transport occurs over Single Mode Fiber (SMF) or Multi Mode Fiber
(MMF). Optical Port 2 ships with factory-installed EMI/weatherproof plug, and must
remain plugged if not in use.
4
STATUS Status LED
Provides a visual indication of the status of the CAP H; see
Determine State of the CAP H" on page 47
5
LOCAL
Mini USB network port
Provides a local connection to a laptop. This port is not required for normal operation
of the unit, and should only be used when requested by CommScope Technical
Support.
6
• AC version—One M8 bolt, hex nut,
and washers
• DC version—Two M6 bolt, hex nut,
and washers
Provides earth ground for the CAP H chassis.
7
MAINS Power connector
• AC version—Provides the power to CAP H models that use standard AC (100 to 240
Vac) power.
• DC version—Provides the power to CAP H models that use DC (-60 to -48 Vdc)
power.
8
ANT2
4.3-10 RF connector
Connect to two separate external antennas or to two ports on a cross-polarized dual
antenna via 50
coaxial cable. Each connector supports two RF bands; see
. These RF ports can be connected directly to an
antenna (using RF jumper cables) or through splitters, allowing additional antennas to
be fed by the CAP H.
9
ANT1
Содержание Era M0201AKB_uc