background image

Mounting instructions

•  This kit shall be installed by trained and qualified personnel only.

•  Only use recommended tools when installing this kit.

•  Do not install this kit on unstable walls or on surfaces which cannot support the weight of the 

device.

•  No water may penetrate into this kit. Therefore, make sure this kit is waterproof towards the wall.

•  Make sure this kit is not subject to torsional forces (e.g. on uneven walls).

•  Install the Intercom station with a distance of min. 150 mm (6 in) downwards to  enable access to the 

locking screws (Tx08).

•  It is recommended to mount the optional Cat. crimp jack C-RJ45-MONT onto the open end of a 

Cat. cable within a flush mount box and to connect the Cat. 6 cable.

Recommended mounting height and position

•  Mount the upper edge of the Intercom station approx. 1,650 mm 

(65 in) from the finished floor. Adapt the mounting height to the 

individual needs.

•  For a barrier-free accessibility, it is recommended to mount the 

Intercom station with enough space to walls or corners.

•  When mounting the Intercom station, pay attention to the cor-

rect camera angle in terms of  accessibility, so that wheelchair 

users and children can be detected by the camera:  

110° (vertical) x 130° (horizontal)

Type: D-BZ-OD5-SH, Version: 1.1/0320 

Commend International GmbH, Saalachstraße 51, A-5020 Salzburg – www.commend.com

Extent of supply

•  Surface mount kit (incl. tamper 

switch)

•  4 mounting screws

•  4 dowels

•  Cat. 6 cable (0.3 m/11.8 in)

•  Short reference

Mounting

OD5 SH

Surface mount kit for an OD5 TD.

 Drill four holes in the wall (see “Dimensions”) and insert the supplied dowels or alternatively 

 prepare a standard double flush mount box for mounting.

 Guide the required cables (Ethernet and USB cable, if needed) through one of the provided cable 

entries (from bottom or rear).

 Install the surface mount kit to the wall using the supplied mounting screws (the locking element 

must be at the lower end).

 If required, connect the tamper switch to a module with an input (e.g. IP Secure Connector or 

EB2E3A-AUD). This input must be configured accordingly via the web interface of the OD5 TD (see 

also manual “

OD5 TD

”).

 Connect the cables. Observe the cable run.

 Insert the Intercom station at the top of the surface mount kit.

 Press the Intercom station with its lower end firmly onto the surface mount kit.

 Turn the locking screw anti-clockwise down as far as it will go using the Tx08  screwdriver (included 

in extent of supply of the OD5 TD). Check whether the lower end of the Intercom station is fixed on 

the surface mount kit.

Manufacturer’s reference

For technical specifications, see the respective data sheet.

For the latest software and documentation, visit: 

www.commend.com

Keep this description in safe custody.

Dimensions

Measuring units in mm (in), not to scale!

23

(0.91)

   11 

2)

  (0.43)

60 (2.36) 

1)

200 (7

.87) 

1)

86 (3.39)

228 (8.98)

1)

 Dimensions for wall holes 

   (ø 5 mm/0.2 in)

2)

 OD5 TD

Отзывы: