LED status indication
GE 800
42
4.2/0617
Interface cards
Interface card G8-V24-PRO / G8-V24-PROIP
Interface card with programmable protocol converter (used for adapting the standard protocol to those
of various external systems). Equipped with two RS-232 interfaces (of which one can be configured as
RS-422). With the software developer kit, own applications can be programmed (e.g. adaptation to vari-
ous video switchers). For more information as well as LED status indication, see the current manual
“
G8-V24-PRO-IP
”.
Interface card G8-IF (2nd generation)
Powerful IP interface card with up to 4 virtual TCP/IP interfaces for using the ICX protocol via IP net-
works. Equipped with two 9-pin D-Submin connectors for output via RS-232 interface port. This allows
for integrating third party systems (e.g. video switcher, access control systems or host computers) to
Intercom Servers via IP networks or RS-232 using the Commend standard protocol.
Interface card G8-IF
LED status indication “RUN”
LED blinks in rhythm of one second: the card is working correctly.
LED is permanently off: no power or hardware fault.
LED is permanently on: waiting for connection to the main processor (during initialising) or reset.
LED blinks fast: card inserted in wrong slot.
LED status indication “subscribers“ (S1 to S4)
LED on: TCP connection established.
LED off: no connection configured.
LED blinks in rhythm “definition error” (
): connection configured, but no TCP connec-
tion.
LED blinks fast: faulty configuration or active establishing of a connection is not possible.
LED status indication “interfaces” (S5 to S6)
LED on: ready for data transmission.
LED off: no data transmission possible.
LED flickers: data are transmitted.
RUN
S1
S2
S3
S4
S5 (= RX interface 1)
S6 (= TX interface 1)
S7 (= RX interface 2)
S8 (= TX interface 2)
Status LEDs: