5. Configuration CCT 800
GE 300
24
3.2/0617
Configuration power management
By default, the Intercom Server GE 300 is powered with a 30 W power supply unit, whereby the number
of usable digital subscribers is limited. With using a 60 W (with PRO 800 6.0 or higher) or 70 W power
supply unit, the number of usable digital subscribers can be increased.
Configuration CCT 800
Go to:
Intercom Server > General Settings >
tab
General
Generation
: In this drop-down list, select the entry “2” (2nd generation of the GE
300).
Power Supply [W]
: In this drop-down list, select either the entry “60” or “70” (according to the used
power supply unit) to use the full capacity of the power supply unit.
by default: 30
Go to:
Subscriber > Station properties >
tab
Extended Settings
Deactivate power management
: Activate this checkbox to optimize the power distribution over
all digital subscriber cards if the respective subscriber has an external power supply.
ATTENTION:
The following configuration may only be required for the Intercom Server GE300 (generation 2)!