Control Station Duetto
WebConfig configuration
1.7/1217
35
Configuration: DIGITAL INPUTS
In this section, the settings of the digital inputs of the DUETTO device can be configured.
Configuration WebConfig
CONFIGURATION > DIGITAL INPUTS
The following dialogue appears:
WebConfig “DIGITAL INPUTS”
Digital Input ADC Values
ADC #1
: Shows the state of the analogue-digital converter (ADC) of the digital input 1.
ADC #2
: Shows the state of the analogue-digital converter (ADC) of the digital input 2.
Digital Input #1
and
Digital Input #2
In this drop-down list, the mode of the digital input of DUETTO can be selected. The following modes
are available:
Off
: The digital input is permanently off.
Internal
Reference
: The digital input is supplied by DUETTO itself and the digital input can be
used as floating contact (e.g. relay contacts, push buttons, switches).
External
Reference
: The digital input is supplied by an external power supply (0 to 24 VDC). In
the drop-down list
Reference Voltage (DC)
, select the desired reference voltage.
GOOD TO KNOW: Connector pin assignment and connection options
A description of the connector pin assignment and connection options can be found
.
GOOD TO KNOW: State of the digital input
The digital input is opened at a very high value and short-circuited at a value close to zero.