OUT 2
OUT 2
OUT 2
OUT 2
OUT 1
OUT 1
EP+
EP–
EM+
EM–
MUTE
GND
LINE–
LINE+
IN 1
IN 2
IN 3
GND
Slot for inserting
button label
IP Downlink
(AXIS Camera
+ PoE)
Handset
:
Microphone
Loudspeaker
Expansion bus
OUT2 connection
IP Uplink
+ PoE
LED brightness
+
–
External
loudspeaker
module
IP Stations WS 201 PICA
Connection
Camera illuminator control
By default, the camera illuminator is connected to the main board of the subscriber via
the expansion bus. In CCT 800, the device is shown with an additional device EB2E2A.
Use OUT 1 on the EB2E2A to switch the camera illuminator on and off. It is also pos-
sible to use OUT 1 as attendant contact, e.g. to switch the camera illuminator on at
initiation of a call.
The camera illuminator can also be connected by using OUT 2 of the subscriber. In this
case, it is possible to control the camera illuminator via this contact and the expansion
bus can be used for other devices.
For dimming the camera illuminator use the potentiometer
3
on the camera board.
NOTE
:
It is only possible to use just one relay 2 (OUT 2) connection, i.e. either the screw
terminals or the connector (see connection diagram).
1
2
2
6
2
5
3
1
NET
STAT
PWR
4
Control button
In order to operate the control button, following steps must be performed:
• Loosen screw
1
(Torx T8)
• Turn safety lever
2
outwards
• Push control button
3
• Turn safety lever
4
back into its original position and tighten the screw
1
The control button can be used for reseting the camera to factory default settings:
• Disconnect power from the camera
• Press and hold the control button
3
and reconnect power
• Keep the control button pressed until the LED indicator
4
flashes amber
• Release the control button. If the status LED
4
turns green the process is com-
plete
Attention:
After a reset the camera must be re-configured, as the camera image
would otherwise appear 180° upside down.
AXIS electronic module – Control button
3
2
1