G8-S0/G3-S0-I
Start Up S0 Network
1.1/1010
13
Configuration CCT 800
Read out the configuration of the Intercom Servers one after the other and carry out the following de-
finitions for all Intercom Servers .
Interfaces
>
S0 >
Tab
Telephone - Features
In the field
Own Tel-No.
the telephone number of the own ISDN connection has to be entered (max.
24 digits).
At
Dial prefix
a number (max. 4-digits, input of 0 to 9, * or #), to be automatically pre-dialled can be
defined, e.g. an exchange number for dialling out, or for selecting a certain provider.
Additionally the type of connection must be selected in the field
Connection type
.
Interfaces
>
S0-Connections >
Server-ID - Description
Open the folder
S0
in the tree structure and click on the connected Intercom Server. Right click in the
right hand window pane and select
Add new entry
for all connected Servers.
For each Intercom Server the following definitions have to be carried out:
In the field
Target Intercom Server
the connected Intercom Server is selected (if the target Inter-
com Server is not yet defined in CCT, the Server-ID of this Intercom Server is entered. The field will
be completed at the first connection to this Server).
In the field
Target-Tel.-No.
the telephone number of the ISDN connection to the other Intercom Ser-
ver housing is entered (max. 24 digits).
At
Auto separating after [sec.]
the time, after which the G8-S0/G3-S0-I hooks on after the call has
been cancelled, can be defined.
Minimum 3 seconds = recommended time (Standard).
In the field
ID number subscriber
at least one code number (multiple entries separated by
commas) must be entered for selection of the partner Intercom Server (
). Per Intercom Server a maximum of 100 code numbers can be configured.
In the field
Reserved own Tel-No.
one of the telephone numbers defined at “Own Tel-No.“ for this
Intercom Server can be selected (example
The field
Dialling-repetitions
defines the number of attempts to establish a connection (while no
connection is existing).
Via the checkbox
Constant retry time
, the irregular retry time can be changed into a constant retry
time.
The checkbox
Offlinemode
is used for maintenance purposes. It prevents the establishment of a con-
nection from the Intercom Server to the maintenance central. However a connection from the mainte-
nance central to the Intercom Server is possible.
The checkbox
Fallback mode
is activated for redundant connections. Details see manual
“PRO 800“.
At
Status check time
, a time (between 1 minute up to 3 days) for network monitoring can be de-
fined. Details see manual “PRO 800“.
The field
Input for status-indication
is required for network monitoring. Details see manual
“PRO 800“.