Functions & configuration
EB8E4A
18
1.0/0315
Light control in front of the cell
It is possible to install a light switch in front of the prison cell for switching on the light. For further in-
formation,
see ”Wiring example” on page 16
Light withdrawal
Via ICX messages or the control desk, it is possible to activate light withdrawal for each prison cell in-
dividually so that the light can no more be switched on in the cell. In this case, the function “light at
attendance” is still available (
see ”Light at attendance” on page 17
). Furthermore, the light can be
switched on permanently so that it is no longer possible to switch off the light in the cell.
The function “light permanently on” is only available with the input “indicator status light”. If the “in-
dicator status light” input is not activated after switching “attendance”, the latching relay will be ener-
gised every ten seconds until the input is activated.
Light withdrawal
Light permanently on
Commands from the Intercom Server
Task
Type
Parameter 1
Parameter 2
Activate light withdrawal
45
7E
Call number cell
9004
Deactivate light withdrawal
45
7E
Call number cell
9005
Retrieve light withdrawal status
45
7E
Call number cell
9006
Messages from the Intercom Server
Task
Type
Parameter 1
Parameter 2
Light withdrawal inactive
45
51
Call number cell
0000
Light withdrawal active
45
51
Call number cell
0001
Commands from the Intercom Server
Task
Type
Parameter 1
Parameter 2
Activate light withdrawal
45
7E
Call number cell
9008
Deactivate light withdrawal
45
7E
Call number cell
9009
Retrieve light withdrawal status
45
7E
Call number cell
900A
Messages from the Intercom Server
Task
Type
Parameter 1
Parameter 2
Light withdrawal inactive
45
52
Call number cell
0000
Light withdrawal active
45
52
Call number cell
0001