8.2.2 Operating temperature shall be kept from 0C to 30C, Humidity shall be kept from
50% to 60%.
8.2.3 Power source shall be supplied at a convenient place for grounding and
maintenance.
8.2.4 The system shall be installed to keep away from the electronic devices such as
monitor, computer, etc.
8.3 How to connect between DSS and Master station
As the related drawing no. 9-3, insert the plate cable and fix with B. K. T.
8.4 How to connect among the Master stations Mater station shall be connected with
9 piece of cable.
1) Black : 24V
2) Brown : GND
3) Red : Call
4) White : Receiver
8.5 Bed Connection
8.5.1 Bed Connection
- It shall be connected between bed and bed with 4P connector.
8.5.2 Emergency Switch (Toilet) Connection
- It shall be connected at the closest sub station, connected in 3P connector
(CN6) no.1, 2.
8.5.3 Emergency Switch (Shower Room) Connection
- It shall be connected at the closest sub station, connected in 2P connector (CN8).
8.5.4 Presence Switch Connection
- It shall be connected at the closest sub station, connected in 3P connector (CN6)
no. 1, 3.
8.5.5 Corridor Light Connection
- It shall be connected at the closest sub station from the presence switch, red lamp
shall be connected in 3P connector (CN5) no. 2, white lamp shall be connected in
3P connector (CN5) no. 5.
8.6 Corridor Toilet Connection
The Corridor Toilet can be connected up to 16ea, refer to the following schematic
for connection.
www.safemag.ru
www.safemag.ru
Содержание JNS-PSM
Страница 14: ...11 9 2 System Wiring Diagram 9 3 Parts Name and Connecting Method www safemag ru www safemag ru...
Страница 15: ...12 9 3 Parts Name and Connecting Method www safemag ru www safemag ru...
Страница 16: ...13 9 4 System Connection Schematic 9 5 Dimension www safemag ru www safemag ru...
Страница 17: ...14 9 5 Dimension 9 5 1 Master Station JNS 1060 9 5 2 Main Control Panel JNS www safemag ru www safemag ru...
Страница 19: ...16 9 5 7 Presence Switch PB 500 9 5 8 Inductor 9 5 9 Corridor Light CL 302C www safemag ru www safemag ru...