background image

Flip back over and slide push pad with motor 

back into exit device. 

11.

Push all the way to the front of device (1) 

and push latch under top of pad. (2)

12.

Once push pad is back inside device. line up the screw 

supplied with the motor kit & the existing hole in the 

housing(1). tighten back screw to hold motor in place.(2)

13.

Slide filler plate back into place. Connect 

to power supply to test and set “ Push to 

Set”, follow steps below.

14.

1

LATCH

2

EXISTING HOLE

1

2

Setting PTS

Step 1-

Select your preferred torque mode (ships in standard torque) Press the 

device push pad to the desired setting. (Recommend to fully depress and 

release 5%, giving the device room for changing door conditions.)

Step 2-

 While depressing the push pad, apply power. (i.e. presenting the credential to 

the reader).

Step 3-

Continue to keep pad depressed, the device will beep 6 times. After the beeps 

have stopped, release the pad and now the adjustment is complete. If not to 

your liking repeat the three steps. 

mm4s switches

on

on

on

on

off

LOW TORQUE

STANDARD TORQUE

HIGH TORQUE

PTS PROGRAMMING LOCKED

off

off

off

CONTINUED

SCREW

U S   c u s t o m e r   s u p p o r t   1 - 8 8 8 - 6 2 2 - 2 3 7 7   |   w w w. c o m m a n d a c c e s s . c o m   |   C A   c u s t o m e r   s u p p o r t   1 - 8 5 5 - 8 2 3 - 3 0 0 2

Содержание PD25-UL-M

Страница 1: ...ew A B C D E F G Command Access is not a licensee or affiliated associated or connected with Allegion Assa Abloy Stanley Schlage Falcon Von Duprin Dorma Sargent Corbin Russwin Yale Emtek Adams Rite Best Precision Arrow Design Hardware Cal Royal Jackson Kawneer AHT Marshall Best Marks Accurate Baldwin FSB PDQ Lawrence Trans Atlantic Hager LSDA General Lock or Omnia or any of their subsidiaries or a...

Страница 2: ...then device attempts to retract again After 3rd fail 5 beeps every 7 minutes device will not attempt to retract To Reset Depress bar for 5 seconds at any time Device is recording it s new position and power mode after the 6th beep Troubleshooting Diagnostics 4 Beeps Failed Sensor Verify all 3 sensor wires are installed correctly Replace sensor if problem persists by contacting office Important Inf...

Страница 3: ...cess power supplies at our factory For more information click here or go to our website Retrofit 2 pin Connector The new 2 pin connector is used when retrofitting a older Command or Von Duprin installation so you can plug in to the exisiting connector PUSH N GO Connector New Exisitng Electrified Exit Device Installation Example Non polarity sensItive U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2...

Страница 4: ...ng dogging Installation Instructions 1 3 When top push pad is removed flip the device over and remove dogging screw 5 2 Once removed slide push pad assembly out the back of the device 4 U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 0 0 2 ...

Страница 5: ...tom dogging hole Do not tighten until device is assembled Once kit is connected flip device over and put screws back in dogging holes 1 2 3 4 5 6 Remove roll pin SUPPLIED WITH PD25 Kit 3 and line up holes on attaching bracket to device holes 4 Push roll pin through kit and device holes and attach C clips 5 Once attached attaching bracket is secure 6 6 7 8 9 10 CONTINUED U S c u s t o m e r s u p p...

Страница 6: ... standard torque Press the device push pad to the desired setting Recommend to fully depress and release 5 giving the device room for changing door conditions Step 2 While depressing the push pad apply power i e presenting the credential to the reader Step 3 Continue to keep pad depressed the device will beep 6 times After the beeps have stopped release the pad and now the adjustment is complete I...

Отзывы: