Flip back over and slide push pad with motor
back into exit device.
11.
Push all the way to the front of device (1)
and push latch under top of pad. (2)
12.
Once push pad is back inside device. line up the screw
supplied with the motor kit & the existing hole in the
housing(1). tighten back screw to hold motor in place.(2)
13.
Slide filler plate back into place. Connect
to power supply to test and set “ Push to
Set”, follow steps below.
14.
1
LATCH
2
EXISTING HOLE
1
2
Setting PTS
Step 1-
Select your preferred torque mode (ships in standard torque) Press the
device push pad to the desired setting. (Recommend to fully depress and
release 5%, giving the device room for changing door conditions.)
Step 2-
While depressing the push pad, apply power. (i.e. presenting the credential to
the reader).
Step 3-
Continue to keep pad depressed, the device will beep 6 times. After the beeps
have stopped, release the pad and now the adjustment is complete. If not to
your liking repeat the three steps.
mm4s switches
on
on
on
on
off
LOW TORQUE
STANDARD TORQUE
HIGH TORQUE
PTS PROGRAMMING LOCKED
off
off
off
CONTINUED