INSERT Instructions
The Command Access MLRK1-KAWP is a field-installable motorized latch-retraction kit for the
Kit Includes
A.
60417 – MLRK1 motor
B.
50944 - molex pigtail
C.
50030 – 6’ power cable
D.
60708/51186 – MM4T REMOTE MODULE
E.
51198 – Remote Module Cable
F.
40059 – (x2) CABLE MOUNTING PAD
G.
40060 – (x2) CABLE TIES
H.
40306 – PhiLLIPS SCREWS (x4)
Kawneer Paneline series exit devices.
A.
B.
F.
H.
G.
E.
D.
C.
INSTALLATION VIDEO
REQUIRED COMMAND Power Supplies:
Use a PS210/220/440B
All Command Access exit devices & field installable kits have been thoroughly cycle tested with Command Access power
supplies at our factory. If you plan on using a non-Command power supply it must be a filtered & regulated linear power supply.
SPECIFICATIONS
• SPDT - Rated .5a @24V
• green= Common (C)
• Blue = normally open (NO)
• grey = normally closed (NC)
Optional built-in rex
• Input Voltage: 24-25.3VDC
• AVERAGE low Torque LATCH RETRACTION CURRENT: 900 mA
• Average high torque latch retraction current: 2A
• Average holding current: 215 ma
• Wire gauge: Minimum 18 gauge
• Direct wire run - no relays or access control units in-between power supply & module