background image

3

12VAC/DC

24VAC/DC

or

Power
Supply

Bridge Rectifier

Energy Transfer Hinge

Switch

EU (Fail Secure)

EU (Fail Secure)

12VAC/DC

24VAC/DC

or

Power
Supply

Bridge Rectifier

Energy Transfer Hinge

Switch

EL (Fail Safe)

EL (Fail Safe)

Step 1 - The door must be preped according to origional manufactures 

 

 template, machined with a 3/8” wire raceway,  & preped for  

              a energy transfer hinge.  

                       Make sure the mortise pocket is free of debris. 

Step 2 - Run the wires from the ETH hinge through the 3/8” race-   

             way starting at the ETH hinge & exiting into the mortise  

             pocket.  

Step 3 - Screw the ETH hinge to the door. At this time DO NOT  

             connect the hinge wires on the jamb side to the wires  

             coming from the power supply. 

Step 4 - Connect the wires exiting the mortise pocket to the  

             Bridge Rectifier (included). 

Step 5 - Connect the Bridge Rectifier to the plug exiting the  

              mortise chassis. 

Step 6 - Carefully slip the connected mortise lock chassis into 

              the mortise pocket paying close attention not to pinch  

              any wires 

Step 7 - Mount the chassis per manufacturer’s instructions. 

Step 8 - Connect the wires from the power supply at the ETH 

              hinge on the jamb side. Connect the hinge to the  

              jamb. 

Mortise 

Lock  

Pocket 

3/8 Wire Raceway 

ETH Hinge Pocket 

 Bridge 

Rectifier 

 

Wire Transfer Hinge 

 Bridge 

Rectifier 

Plug 

3/8 Wire Raceway 

 

Mortise 

Lock  

Pocket 

Mortise 

Lock  

Pocket 

Mortise 

Lock  

Pocket 

For Lever Control Solenoid on LPM models 183-188 Only

All other models skip to next page

Отзывы: