background image

2

Note: 

For LPM1 series option placement is only 

recommended for Hollow metal doors. For wood doors, use 

standard placement above ceiling tile or in junction box.

Module

Ceiling Tile

LPM1 Series Installation 

Example

Mod
ule

Standard Placement

Hinge Pocket

Option Only

Standard Placement

Optional Placement

1.   The door must be prepared with a standard type 86 mortise lock preparation and  a 3/8” wire 

raceway.  Be sure that the mortise pocket and the raceway are clear of debris prior to installation.

2.   Install the 3-prong, 72” wire harness through the wire raceway leaving enough slack to “quick 

connect” to the mortise chassis.

3.   Install PM300 at the hinge jamb side of the door within 120” of the lockset.  Connect the 3-prong wire 

harness to the PM300 and hard wire it directly to the harness from the lockset (if using an electric 

hinge or other transfer device, use 18ga wire). 

4.   Connect the 2-prong input power wires (BLACK and BLACK) of the PM300 to the 2-prong, 72” wire 

lead.  Then connect the 72” wire lead directly to the wire run coming from the 26.5VDC power supply 

(not included).  The power supply may be up to 300 feet away (see power supply wiring instructions).  

Note: these wires are not polarity sensitive.