1. Above electrical wiring diagram only for your reference, please subject machine posted the wiring
diagram.
2. The swimming pool heat pump must be connected ground wire well, although the unit heat exchanger
is electrically isolated from the rest of the unit. Grounding the unit is still required to protect you against
short circuits inside the unit.
Disconnect:
A disconnect means (circuit breaker, fused or un-fused switch) should be located within sight of
and readily accessible from the unit. This is common practice on commercial and residential heat pumps. It
prevents remotely-energizing unattended equipment and permits turning off power at the unit while the unit is
being serviced.
4. Display controller operation
4.1.
The buttons of the LED display
When the heat pump is running, the LED display shows the water inlet temperature.
-
LED 1 is on when the compressor is running.
-
LED 2 is on in case of a malfunction
4.2.
Turn on/off the heat pump
Press to turn on the heat pump, the LED display shows the water setting temperature for 5 seconds, then
shows the water inlet temperature.
Press again to turn off the heat pump.
4.3.
Set the water temperature
Press
or
directly to adjust water temperature (range: 10
– 42°C).
Press to save the setting, then exit.
Attention!
The heat pump can only run if the water is circulating / the filtration system is running.
Содержание EasyHeat 2
Страница 1: ...EasyHeat ZWEMBAD WARMTEPOMP GEBRUIKS EN ONDERHOUDSHANDLEIDING POOL HEAT PUMP USER AND SERVICE MANUAL...
Страница 6: ...6 1 2 Afmetingen EasyHeat 2...
Страница 7: ...7 EasyHeat 4...
Страница 11: ...11 3 Elektrische bedrading 3 1 EasyHeat 2 3 2 EasyHeat 4...
Страница 20: ...20 1 2 Dimension EasyHeat 2...
Страница 21: ...21 EasyHeat 4...
Страница 25: ...25 3 Electrical wiring 5 1 EasyHeat 2 5 2 EasyHeat 4...
Страница 32: ......