WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.

—  Do  not  store  or  use  gasoline  or  other  flammable 

vapors and liquids in the vicinity of this or any other 

appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any 

phone in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

—  Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

VENT-FREE FREESTANDING PEDESTAL STOVE SYSTEM

OWNER’S OPERATION AND INSTALLATION MANUAL

THERMOSTATICALLY - CONTROLLED MODELS 

S26PTA AND S26NTA

20,000 TO 26,000 BTU/HR

Содержание S26NTA

Страница 1: ...T TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas s...

Страница 2: ...ating plate This appliance is not convert ible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer State of Massachusetts The installation must be m...

Страница 3: ...may be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this replace WARNING Any ch...

Страница 4: ...ions in Cleaning and Maintenance page 16 10 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapors from these products may create a white powder resi...

Страница 5: ...ion and ventilation air Read the following instructions to insure proper fresh air for this and other fuel burning appliances in your home Today s homes are built more energy ef cient than ever New ma...

Страница 6: ...s between the rooms AIR FOR COMBUSTION AND VENTILATION Continued 1 Determine the volume of the space length x width x height Length x Width x Height __________cu ft volume of space Example Space size...

Страница 7: ...rills or ducts You must provide two permanent openings one within 12 of the ceiling and one within 12 of the oor Connect these items directly to the outdoors or spaces open to the outdoors These space...

Страница 8: ...naturalorpropane LP Ifyourgas supply is not correct do not install heater Call dealer where you bought heater for proper type heater WARNING This appliance is equipped for natural or pro pane LP gas F...

Страница 9: ...sure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 6 Pointing the vent down protects it from freezing rain or sleet INSTALLATION Contin...

Страница 10: ...CHECKING GAS CONNECTIONS WARNING Testallgaspiping and connections internal and external or unit for leaks after installing or servicing Correct all leaks at once WARNING Never use an open ame to check...

Страница 11: ...essed air 3 Check all joints from gas meter to equipment shutoff valve see Figures 9 and 10 Apply noncorrosive leak detection uid to gas joints Bubbles forming show a leak 4 Correct all leaks at once...

Страница 12: ...ctangular opening in the rear panel see Figure 15 6 Remove the two blower mounting brackets from the rear panel by removing two screws each see Figure 16 page 13 7 Attach the two mounting brackets to...

Страница 13: ...nto a convenient 3 prong grounded wall receptacle near the stove WARNING ElectricalGround ing Instructions This appliance is equipped with a three prong grounding plugforyourprotec tion against shock...

Страница 14: ...afety information above 2 Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait ve 5 minutes to clear out any gas Then smell for gas including near t...

Страница 15: ...ulating down in most cases MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 under Lighting Instructions page 14 2 Depress control knob and light pilot with match 3 Keep control knob pressed in for...

Страница 16: ...in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the pilo...

Страница 17: ...S26NTA Btu Variable 20 000 26 000 20 000 26 000 Type Gas Propane LP Only Natural Only Ignition Piezo Piezo Manifold Pressure 8 W C 3 0 W C Inlet Gas Pressure in of water Maximum 14 10 5 Minimum 11 5...

Страница 18: ...stalled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Kee...

Страница 19: ...trol knob pressed in 30 seconds 3 Fully open equipment shutoff valve 4 A Contact local gas com pany B Clean ODS pilot see Cleaning and Maintenance page 16 or replace ODS pilot assembly 5 Hand tighten...

Страница 20: ...r is re moved from line Have gas line checked by local gas company 3 Observe minimum installation clearances see page 8 4 Clean burner see Cleaning and Maintenance page 16 or replace burner ori ce 1 P...

Страница 21: ...ially clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between con trol valve and burner 2 Gas leak See Warning statement above 1 Excessive line or manifold pr...

Страница 22: ...www desatech com 110361 01F 22 ILLUSTRATED PARTS BREAKDOWN MODELS S26PTA AND S26NTA SHOWN 9 3 2 6 5 8 4 1 12 13 11 10 9 7 14...

Страница 23: ...4 109053 01 109053 01 Burner Outlet Tube 1 5 111124 01 111124 01 Burner Retainer Spring 1 6 099056 29 099056 27 Burner Ori ce Injector 1 7 101329 26 101329 20 Gas Control Valve Kit 1 8 102980 01 10298...

Страница 24: ...www desatech com 110361 01F 24 ILLUSTRATED PARTS BREAKDOWN MODELS S26PTA AND S26NTA 1 4 14 3 2 14 7 16 15 11 18 10 13 5 6 9 8 17 12...

Страница 25: ...5 108932 01CK Louver Panel 1 6 105657 01 Blower Bracket 2 7 107363 01 Door 1 8 Firebox Back Panel 1 9 Firebox Floor 1 10 108939 01CK Firebox Top Assembly 1 11 110419 01CK Screen Assembly 1 12 101382 0...

Страница 26: ...672 6040 for referral information When calling DESA Heating Products have ready model number of your heater the replacement part number ACCESSORIES Purchase these heater accessories from your local d...

Страница 27: ...KY 42103 3414 270 846 1199 1 800 654 8534 Fax 1 800 846 0090 franktalk aol com Master Parts Dist 1251 Mound Ave NW Grand Rapids MI 49504 2672 616 791 0505 1 800 446 1446 Fax 616 791 8270 www nbmc com...

Страница 28: ...stallation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENTALLOWED BYTHE...