background image

Содержание CGD3924NT

Страница 1: ...er appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your build ing Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call the fire department m Installation and service must be per formed by a qualified installer service agency or ...

Страница 2: ...completely before trying to assemble operate or service this heater Improper use of this heater can cause serious injury or death from burns fire explosion electrical shock end carbon monoxide poisoning A DANGER Carbon monoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs t...

Страница 3: ...a qualified service person Note During initial operation slight smoking could occur due to log curing and heater burning manufacturing residues 9 Do not allow fans to blow directly into the fireplace Avoid any drafis that a ter burner flame patterns Ceiling fans can create drafts that alter burner flame patterns Alteled burner patterns can cause sooting 10 Do not use a blower insert heat exchanger...

Страница 4: ...ase assembly by grate 2 Remove all protective packaging applied to logs and heater for shipment 3 Check all items for any shipping damage If damaged promptly inform dealer where you bought heater Operation This heater is clean burning It requires no outside venting There is no heat loss out a vent or up a chimney Heat is generated by realistic dancing yellow flames This heater is designed for vent...

Страница 5: ...und doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction iou must provide additional fresh air Unusually tight construction is defined as construction where a walls and ceilings exposed to the outside atmosphere have a continu ous water vapor retarder with a rating of one perm or less with open ings gasketed or sealed an...

Страница 6: ...nted gas heater Btu Hr Gas fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Example Gas water heater 40 000 Btu Hr Vent free heater 39 000 Btu Hr Total 79 000 Btu Hr Do nut include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used Btu Hr maxim...

Страница 7: ...d size of ventitation grills or ducts WARNING Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Ventilati_ Grills Into Adjoining Or Room Remove i Option 1 Door into I_ Adjoining Ii Room OptionOI Ventilation Grills Into Adjoining Room Option 2 Figure 2 Ventilation Air from Inside Building Ventil...

Страница 8: ...ARNING Never install the heater in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 36 inches from the front top or sides of the heater in high traffic areas in windy or drafty areas CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth...

Страница 9: ...Front Width 18 17 14 20 24 17 14 26 30 17 14 32 Carefully follow the instructions below This will ensure safe installation into a masonry or U L listed manufactured fireplace Minimum Wall and Ceiling Clearances see Figure 4 A Clearances from the side of the fireplace opening to any combustible wall should not be less than 16 inches B Clearances from the top of the fireplace opening to the ceiling ...

Страница 10: ... extend at least 8 up for all models If non combus tible material is less than 12 you must install the fireplace hood accessory 24 and 30 models only See chart below and Figure 5 for minimum clearances MPOBTANT If you cannot meet these minimum clearances you must operate heater with chimney flue damper open Go to lnstalli_Tg Damper Clamp Acce ssot 3 for Vented Operation page 13 Non Combustible Mat...

Страница 11: ...ge 13 Non Combustible Material Distance A 12 or more Between 8 and 12 Less than 8 Requirements for Safe Installation Non combustible material okay 24 or 30 Models Install fireplace hood acessory GA6050 or GA6052 see Accessories page 33 18 Model Non combustable material okay Non combustible material must be extended to at least 8 See Between 8 and 12 above If you cannot extend material you must ope...

Страница 12: ...y with the flue damper open OR raise the mantel to an acceptable height OR remove the mantel Floor Clearances A If installing appliance on the floor level you must maintain the minimum distance of 14 to combustibles see Figure 8 Combustible 14 Material _ 1 _ XNon Combustible Material Figure 8 Minimum Fireplace Clearances ff Installed at Floor Level B Ifcombustible materials are less than 14 to the...

Страница 13: ...n If reasons number I or 2 above apply to you you must permanently open chimney flue damper You must install the damper clampaccessory toorder seeAccessories page 33 This will insure vented operation see Figure 10 The damper clamp will keep damper open Installation instructions are included with clamp accessory See chart below for minimum permanent flue opening you must provide Attach damper clamp...

Страница 14: ...lb in mounting bracket Installation Items Needed hardware package provided with heater approved flexible gas hose not provided if allowed by local codes sealant resistant to propane propaneLP gas not provided electric drill with 3 16 drill bit 1 Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator Connect approved flexible gas hose to gas regulator of h...

Страница 15: ... Gas j Regulator Flexible Gas Hose if allowed by local codes Fitting Figure 11 Attaching Flexible Gas Hose to Heater Gas Regulator Masonry Screw L i Mounting Bracket Figure 12 Attaching Base Assembly to Fireplace Floor I 102990 ...

Страница 16: ... be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occur Installation must include a manual shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be up stream from heater see Figure 13 page 17 Apply pipe joint sealant lightly ...

Страница 17: ... page 33 Minimum inlet pressure for purpose of input adjustment CHECKING GAS CONNECTIONS WARNING Test all gas piping and connections for leaks after installing or servicing Correct all leaks at once WARNING Never use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming show a leak Correct all leaks at once Pressure Testing gas Supply Piping syste...

Страница 18: ... joints Bubbles forming show a leak 4 Correct all leaks at once Pressure Testing Heater Gas Connections 1 Open manual shutoff valve see Figure 14 2 Open main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from manual shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles forming ...

Страница 19: ...ut of the back log The cutout on the fight of the middle log should fit over the burner see Figure 17 Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is centered over the burner U bend 3 Locate the recesses on the back of the front log 3 Fit these recesses between the posts of the grate base see Figure 18 4 Locate the notches in the bottom of the ...

Страница 20: ...rol which has been under water LIGHTING INSTRUCTIONS WARNING If fireplace has glass doors never operate this heater with glass doors closed If you operate heater with doors closed heat buildup inside fireplace will cause glass to burst Also if fireplace opening has vents at the bottom you must open the vents before operating heater You must operate this heater with a fireplace screen in place Make...

Страница 21: ...re 21 Pilot If control knob does not pop out when released contact a qualified service person or gas supplier for repairs 8 Slightly depress and turn control knob counterclockwise _ to desired heating level The burner should light Set control knob to any heat level between HI and LO WARNING Do not operate heater between PILOT and HIGH positions VARIABLE CONTROL OPERATION The variable control valve...

Страница 22: ... will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGH...

Страница 23: ...r to remain fully on without modulating down in most cases MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 under Lighting Instructions page 23 2 Depress control knob and light pilot with match 3 Keep control knob pressed in for 30 seconds after lighting pilot After 30 secomls release control knob Now follow step 8 page 23 Check pilot flame pattern and burner flame patterns often PILOT FLAME P...

Страница 24: ...en released contact a qualified service person or gas supplier for repairs 6 With control knob pressed in press and release ignitor button This will light pilot The pilot is attached to the front burner If needed keep pressing ignitor button until pilot lights Note If pilot does not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with matc...

Страница 25: ...ed or larger WARNING Turn off and unplug heater and let cool before servicing Only a qualified service person should service and repair heater CAUTION Never use a wire needle or similar object to clean ODS pilot This can damage ODS pilot unit OBSERVED POSSIBLE PROBLEM CAUSE REMEDY When ignitor button Is pressed there is no spark at ODS pilot l Ignitor electrode not con nected to ignitor cable 2 Ig...

Страница 26: ...embly 6 Replace gas regulator ODS pilot lights but flame goes out when control knob is released 1 Control knob not fully pressed in 2 Control knob not pressed in long enough 3 Manual shutoff valve not fully open 4 Pilot flame not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Di...

Страница 27: ...ight smoke or odor during initial operation I Not enough air 2 Gas regulator defective 3 Residues from manu facturing processes and logs curing 1 Check burner for dirt and debris If found clean burner see Cleaning and Mainte nance page 25 2 Replace gas regulator 3 Problem will rtop after a few hours of operation Moisture condensa 1 Not enough combus 1 Refer to Air for Com tion noticed on tion vent...

Страница 28: ...T statement above 2 Gas leak See Warning 2 statement at top of page Open window and ventilate room Stop using odor causing products while heater is running Locate and correct all leaks see Checking Gas Connections page 17 Heater shuts off in use ODS operates 1 Not enough flesh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Open window and or door for ventilation 2 Contact ...

Страница 29: ...Gas Valve Mounting Thermostat Bracket Sensing Bulb Figure 26 Location of Gas Valve Assembly and Thermostat Sensing Bulb 2 The adhesive backed mounting clip see Figure 27 is attached to the thermostat sensing bulb Remove the adhesive backed mounting clip Figure 27 Adhesive backed Mounting Clip 3 With 1 4 hex driver or socket loosen the thermostat screw Carefully slide the thermostat sensing bulb ou...

Страница 30: ...b Mounting Clip Glass Doors Figure 31 Installing Thermostat Sensing Bulb behind Glass Doors 5 The mounting clip must be a minimum of 3 from bottom of fireplace to prevent crimping of capillary Once you have decided on a location clean the area thoroughly Remove the paper backing from the adhesive on back of mounting clip Press the clip into the new location so that the thermostat sensing bulb will...

Страница 31: ...Gas Only Ignition Piezo Piezo Piezo Manifold Pressure 3 5 W C 3 5 W C 3 5 W C Inlet Gas Pressure in of water Maximum 10 5 10 5 10 5 Minimum 5 Shipping Weight 28 lbs 30 lbs 32 lbs For the purpose of input adjustment When gas pressure is too low pilot will not stay lit burners will have delayed ignition heater will not produce specified heat When gas quality is bad pilot will not stay lit burners wi...

Страница 32: ...oviding original replacement parts and accessories Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 All States 219 462 7441 1 800 362 6951 Washer Equipment Co 1715 Main Street Kansas City MO 64108 KS MO AR 816 842 3911 East Coast Energy Products 833 Broadway W Long Branch NJ 07764 ...

Страница 33: ...TOFF VALVE GA5010 For all models Manual shutoff valve with 1 8 NPT tap Fits i 2 NPT pipe BLACK FIREPLACE HOOD GA6050 For all models Helps deflect heat away from mantel or wall above fireplace BRASS FIREPLACE HOOD GA6052 For all models Helps deflect heat away from mantel or wall above fireplace DAMPER CLAMP GA6080 For variably controlled models Permanently opens chimney flue damper for vented opera...

Страница 34: ...ILLUSTRATED PARTS BREAKDOWN Variable Manually Controlled Models CGD3018N CGD3924N CGD3930N 12 I d I I I 3 18 20 1 20 6 J J 17 15 ...

Страница 35: ...R 102844 01 102966 01 098867 11 102798 01 102779 01 099056 16 102843 01 102772 01 102568 05 098508 01 098354 01 102445 01 099387 08 098271 07 103042 01 099594 01 098593 01 M 11084 38 098304 03 098276 01 098249 01 099553 01 DESCRIPTION QTY Back Log 1 t Middle Log 2 1 Front Log 3 t Crossover Log 4 t Painted Base Assembly 1 Lower Bracket 1 Upper Bracket 1 Gas Regulator 1 Inlet Tube 1 Outlet Burner Tu...

Страница 36: ...ILLUSTRATED PARTS BREAKDOWN Thermostatically Controlled Manuals 2 CGD3924NT 12 20 1 20 18 24 17 22 23 19 13 21 25 14 8 15 I o 22 _j 16 ...

Страница 37: ...9 01 25 099211 01 DESCRIPTION QTY Back Log 1 1 Middle Log 2 1 Front Log 3 1 Crossover Log 4 1 Painted Base Assembly 1 Lower Bracket 1 Upper Bracket 1 Gas Regulator 1 Inlet Tube 1 Outlet Burner Tube 1 Burner Orifice Injector 1 Burner Clip 1 Burner 1 Thermostat Gas Valve Assembly 1 Thermostat Bracket 1 Thermobulb Clip 1 Piezo ignitor 1 Pilot Tube 1 Ignitor Cable 1 ODS Pilot 1 Ignitor Electrode 1 The...

Страница 38: ...NOTES ...

Страница 39: ...NOTES tm 102990 ...

Страница 40: ...ons furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the...

Отзывы: