Comfort Flame Biltmore24LMN Скачать руководство пользователя страница 1

PIL

OT

 

O

F

F

 

O

N

 

LO

REMOTE

OFF

HI

24" AND 30" REMOTE CONTROL READY

BILTMORE™ SPLIT OAK

LOG AND BURNER SETS:

BILTMORE24LMN/LMP AND BILTMORE30LMN/LMP

Also Design-Certified As Vented Decorative Appliances 

When Not Used With Hand-Held Thermostat Remote

 

 

Biltmore24LMN
Biltmore24LMP

Biltmore30LMN
Biltmore30LMP

 -  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance.

 -  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 

•  Do not touch any electrical switch; do not use any phone in your building. 

•  Leave the building immediately.

• Immediately call your gas supplier from a neighbor’s phone.  Follow the gas supplier’s instructions. 

•  If you cannot reach your gas supplier, call the fire department.

 -  Installation and service must be performed by a qualified installer, service agency or the gas supplier.

       WARNING:
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious injury, death, or property damage.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not 

prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This 

appliance is not convertible for use with other gases.

Installation and Operation Instructions

Models

PFS

®

US

C

Report No. F09-126

P/N 900556-00   Rev. NC   12/2015

Biltmore

TM

 Unvented (Vent-Free) Gas Log Heaters

WELCOME HOME TO WARMTH

TM

P900556-00

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions 

for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation 

section on page 5 of this manual.

Содержание Biltmore24LMN

Страница 1: ...by a qualified installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage INSTALLER...

Страница 2: ...ng plate This appliance is not convertible for use with other gases WARNING Do not allow fans to blow directly intotheappliance Avoidanydraftsthatalterburner flame patterns Ceiling fans can create dra...

Страница 3: ...P units only 3 To prevent performance problems the use of a propane LP fuel tank of less than 100 lb capacity is not recommended propane LP units only 4 If you smell gas shut off gas supply do not try...

Страница 4: ...are required thermostat operation is not permitted State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas sachusetts Sellers of unvented p...

Страница 5: ...onstruction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fre...

Страница 6: ...space can support with the actual amount of Btu Hr used _______ Btu Hr maximum the space can support _______ Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 79...

Страница 7: ...heatsource WARNING Never install the heater in a bedroom or bathroom unless installed as a vented appliance see page 10 in a recreational vehicle where curtains furniture clothing or other flam mable...

Страница 8: ...irebox follow firebox manufacturer s instructions for minimum clear ances to combustible materials B Clearances from top of fireplace opening to ceiling should not be less than 42 LOG SIZING REQUIREME...

Страница 9: ...a Hood If minimum clearances in Figure 6 are not met you must have a hood When using a hood there are still certain minimum mantel clearances required Follow minimum clearances shown in Figure 7 when...

Страница 10: ...u must maintain the minimum distance of 14 to combustibles see Figure 8 B If combustible materials are less than 14 to the fireplace you must install appliance at least 5 above the combustible floorin...

Страница 11: ...ter heater base and logs front to back and side to side in fireplace 6 Carefully remove logs without moving heater base 7 Mark screw locations through holes in mounting flanges see Figure 12 If instal...

Страница 12: ...al regulator with the vent pointing down as shown in Figure 13 Pointing the vent down protects it from freezing rain or sleet CAUTION Use only new black iron or steel pipe Internally tinned copper tub...

Страница 13: ...ne LP supply tank to equipment shutoff valve for propane LP gas see Figure 16 or from gas meter to equipment shutoff valve for natural gas see Figure 17 Apply noncorrosive leak detection fluid to gas...

Страница 14: ...ingers Make sure front log rests firmly between grate fingers and grate base see Figure 18 2 Place base of middle log 2 in the U shaped slots of grate base The cutout on the right of middle log should...

Страница 15: ...s on bottom of crossover log 7 Slide onto pegs located in crossover log 6 and middle log 2 See Figure 24 8 Add volcanic stone around base of heater if desired Do not place any volcanic stone on logs o...

Страница 16: ...to burst Make sure there are no obstructions across opening of fireplace NOTICE Duringinitialoperationofnewheater burn ing logs will give off a paper burning smell Orange flame will also be present O...

Страница 17: ...This will drain the battery CAUTION Do not try to adjust heating levels by using the equipment shutoff valve TO TURN OFF GAS TO APPLIANCE Figure 27 Setting the Selector Switch Control Knob and Flame A...

Страница 18: ...d air holes will create soot We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person We also recommend that you keep the...

Страница 19: ...er REPLACEMENT PARTS See pages 22 23 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Par...

Страница 20: ...ontrol knob not in PILOT position 3 Control knob not pressed in while in PILOT position 4 Air in gas lines when installed 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator s...

Страница 21: ...is removed from line Have gas line checked by local natural or propane LP gas company 3 Observeminimuminstallationclearances see pages 8 10 4 Clean burner see Cleaning and Mainte nance page 18 or rep...

Страница 22: ...ILTMORE30LMP 30 18 19 27 18 23 12 11 14 4 5 1 2 17 10 21 20 22 6 7 3 9 20 16 8 15 29 28 28 25 26 O F F P I L O T O N H I L O O F F P I L O T O N H I L O 24 31 13 NOTE Items 28 and 29 are Natural Gas o...

Страница 23: ...837 J3837 Gas Control Valve LP 1 J3836 J3836 Gas Control Valve NG 1 17 J8109 J8109 J8109 J8109 Lower Bracket 1 18 J1958 J1958 J1958 J1958 Screw 8 x 0 38 7 19 Painted Base Assembly 1 20 J3569 J3569 J35...

Страница 24: ...IHP shall be used in the installation of this appliance Use of non approved accessory part kit can result in poor performance and safety hazards FIREPLACE HOOD BLACK Cat No F1764 Model GA6050 For all...

Страница 25: ...e to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provide...

Страница 26: ...nce uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local d...

Отзывы: