507716-01
Page 21 of 58
Issue 1717
Maximum Allowable Exhaust Vent Lengths with Furnace Installed in a Closet or Basement Using Ventilated Attic or Crawl
Space for Intake Air in Feet
Standard Termination at Elevation 0 - 4,500 ft
Number
of 90°
Elbows
Used
2" Pipe
2-1/2" Pipe
3" Pipe
Capacity
Capacity
Capacity
045
70
90
110
135
045
70
90
110
135
045
70
90
110
135
1
66
51
29
9
n/a
95
95
73
38
n/a
113
112
93
93
89
2
61
46
24
4
90
90
68
33
108
107
88
88
84
3
56
41
19
n/a
85
85
63
28
103
102
83
83
79
4
51
36
14
80
80
58
23
98
97
78
78
74
5
46
31
9
85
75
53
18
93
92
73
73
69
6
41
26
4
70
70
48
13
88
87
68
68
64
7
36
21
n/a
65
65
43
8
83
82
63
63
59
8
31
16
60
60
38
3
78
77
58
58
54
9
26
11
55
55
33
n/a
73
72
53
53
49
10
21
6
50
50
28
68
67
48
48
44
Standard Termination Elevation 4,500 - 10,000 ft.
Number
of 90°
Elbows
Used
2" Pipe
2-1/2" Pipe
3" Pipe
Capacity
Capacity
Capacity
045
70
90
110
135
045
70
90
110
135
045
70
90
110
135
1
66
51
29
n/a
n/a
95
95
73
38
n/a
113
112
93
93
89
2
61
46
24
90
90
68
33
108
107
88
88
84
3
56
41
19
85
85
63
28
103
102
83
83
79
4
51
36
14
80
80
58
23
98
97
78
78
74
5
46
31
9
85
85
53
18
93
92
73
73
69
6
41
26
4
70
70
48
13
88
87
68
68
64
7
36
21
n/a
65
65
43
8
83
82
63
63
59
8
31
16
60
60
38
3
78
77
58
58
54
9
26
11
55
55
33
n/a
73
72
53
53
49
10
21
6
50
50
28
68
67
48
48
44
* Size intake and exhaust pipe length separately. Values in table are for intake OR Exhaust, not combined total. Both Intake and
Exhaust must be same pipe size.
* Additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the total vent length
calculation.
Table 5C.
Содержание GUH95C
Страница 3: ...507716 01 Page 3 of 58 Issue 1717 Figure 1 Parts Arrangement...
Страница 22: ...507716 01 Page 22 of 58 Issue 1717 Figure 25 Figure 26...
Страница 37: ...507716 01 Page 37 of 58 Issue 1717 Figure 59 Trap Drain Assembly Using 1 2 PVC or 3 4 PVC...