An alarm can be signalized by a fast flashing of the LED diode
on the device panel (Optical signalling - LED). In the case that only one
alarm originating from a measurement value is active, a yellow LED is
flashing. In the case that more alarms occur simultaneously,
or a system alarm or an alarm originating from an exceeded memory
occupancy
limit
occur,
a
red
LED
diode
is
flashing.
NOTE: A blue flashing LED diode does not notify an alarm,
but the communication of the radio modem
with the operator’s network.
Besides, an alarm may be signalled acoustically by a characteristic
sound, which is repeated at regular intervals. If the device is connected
to an external power supply, the acoustic signal is more intense
than with battery power.
The operator alerted this way can confirm the acoustical or optical (LED
diode) signal and so mute it until a new alarm occurs (See the chapter
“
Operating the datalogger from the keypad
).
Alarm events - Preferences
_________________________
In the standard mode the alarm lasts only during the time when
the measurement values lie outside the allowed limits. As soon as they
return inside the allowed limits, the alarm will cease. In some cases,
it is desirable for the user to be informed of an alarm that has occurred
during his absence. If you enable the
Latched alarms
choice
in the device setting, then every alarm occurring in the device remains
active until operator intervenes, irrespective of the measurement
values (i.e. until the time of manual cancel). Latched Alarms Memory
can be deleted either from SW Vision and/or by device restart by
buttons (the device Off and On). The availability of these choices
depends on device configuration settings.
Moreover, alarm evaluation may be enabled here for selected days of
the week only and for certain hours of the day. This setting can also be
used for system alarms, but it should not be combined with the above
described option
Latched alarms
.
Alarm events
– Mute of signalling
____________________
In this panel you can enable or disable
the alarm signalization
deactivation
– mute of signalling
. Depending on the device
configuration, deactivation of the signalling can be done either by SW
Vision and / or from the device keypad (in menu item ALARM on LCD).
The alarm signalling
means either optical signalling - by a flashing
LED, or acoustic signalling - by an intermittent tone (beeping).
The alarm deactivation function allows you to deactivate (mute)
the alarm signalling for the duration of the alarm condition
(the corresponding alarm symbol remains on the display).
Deactivation of the signalling can be according to the device configuration:
Содержание U0110G
Страница 5: ...IE LGR UxxxxM 23 5 Dataloggers UxxxxM and UxxxxG U0141M U0141G models...
Страница 61: ...IE LGR UxxxxM 23 61 Dimensions U0110M U0110G U8410M U8410G U0121M U0121G...
Страница 62: ...62 IE LGR UxxxxM 23 U0141M U0141G U3120M U3120G U4440M U4440G...
Страница 63: ...IE LGR UxxxxM 23 63 U3121M U3121G U3631M U3631G...
Страница 64: ...64 IE LGR UxxxxM 23 U0141TM U0141TG U0843M U0843G U5841M U5841G U6841M U6841G U7841M U7841G...