Enter time
Enter 1 time
Exit time
Exit 1 time
21
Timing menu
Enter time
This is the time available to enter an area via the entry/exit zone and disarm the system. If the entry time is exceeded and no
“enter time extension” has been programmed, an alarm is triggered. If a zone is assigned to the “Enter/Exit 1” type, it will observe
the “Enter 1 time” and “Exit 1 time” value. If a zone is assigned to the “Enter/Exit 2” type, it will observe the “Enter 2 time” and
“Exit 2 time” value.
Each area will use the same time (1 or 2)
• Enter 1 time
Enter the time value for the parameter: 0 - 255 seconds
Default: 30 sec.
• Enter 2 time
Enter the time value for the parameter: 0 - 255 seconds
Default: 30 sec.
• Enter time extension
This is a pre-alarm which occurs when the entry time has elapsed. The built-in sounder is activated during this additional
entry delay period. At the end of this entry delay extension, the system triggers a full alarm condition; the external sounder is
activated and an alarm event is indicated on the control panel.
0 - 255 seconds.
Default: 0 sec.
Exit time
The exit time is the period available in which to leave the premises via exit/entry zones and “access” zones while arming is taking
place. If this time period is exceeded, or if an instant alarm zone is activated, a “Fail to arm” event will arise (if this option is
programmed).
The value of the parameter can be set from 0~255 seconds.
The following parameters can be set:
• Exit 1 time
Enter the time value for the parameter. The value of the parameter can be set from 0~255 seconds
Default: 30 sec.
• Exit 2 time
Enter the time value for the parameter. The value of the parameter can be set from 0~255 seconds
Default: 30 sec.