4

Buttons

   

Audio activation

    Lock-release activation

  Buttons 1-2-3-4-5 (programmable)

   

Self activation (programmable)

   

Ringtone activation in silent mode    

 

 

(Privacy mode)

    Audio volume adjustment

    Call volume adjustment

    Increase / Decrease value

   

Contrast adjustment

   

Brightness control

Indicator LED

   

continuous flashing

 = incoming call

LED steady in call

 = communicating

LED  steady in standby

 = 

Automatic answer

  mode 

(Hands-free mode) enabled

   

continuous flashing

 = incoming call 

1 flash

 = confirm lock-release

4 flashes

 = programming successful

10 flashes

 = programming error

   

LED steady 

= ringtone in 

silent

 mode

 

(Privacy mode)

3 flashes (every 5 s.)

 = 

Automatic door opening on 

receipt of call mode 

 (Doctor mode) enabled

slow flashing

 = programming

4 flashes

 = device busy

Touch-sensitive button activation

 

f

Swipe to enable the row (1) of function buttons.

 

f

Swipe again to enable the row (2) of adjustment buttons.

 

f

Press the desired button once to activate the function 

associated with it

1
2

Press and hold keys 

(Disabled by default from firmware version 1.5.0)

Pressing and holding keys adds further functions to the door entry monitor.

Carry out the procedure described below to enable - or disable, depending on the factory setting - the press and hold 
feature:

 

Door entry monitor in standby.

1. 

Take note of the S2 DIP-switch settings.

2. 

Enter programming mode by setting S2 DIP-switches 1, 3, 5 to ON.

3. 

Press   to enable (or press   to disable).

4. 

Make sure the 

 key flashes 4 times and the confirmation tone is emitted.

5. 

Restore the initial configuration of the S2 DIP-switches.

Once the enabling procedure is complete, you will be able to enable the following functions:

Automatic door opening on receipt of call (Doctor mode)

 

f

Press and hold (4 sec.) the programmed button (default: Key 3) to enable/disable the function.

Automatic answer (Hands-Free function)

 

f

Press and hold (4 sec.) the audio activation button   to enable/disable the function.

Wait for approximately 1 sec. before pressing 

the same button again. Pressing the same 

button several times in quick succession will 

cancel the command.

Содержание Icona Manager

Страница 1: ...Icona 2 wire door entry monitor Art 6601W Art 6601W BM Passion Technology Design EN TECHNICAL MANUAL...

Страница 2: ...communication systems in residential commercial industrial and public buildings Installation All activities connected to the installation of Comelit products must be carried out by qualified technica...

Страница 3: ...5 6 access to programming DIP 7 for power supply voltage management Paragraph Power supply management on page 9 DIP 8 for setting main and secondary door entry monitor Paragraph Main and secondary do...

Страница 4: ...he function associated with it 1 2 Press and hold keys Disabled by default from firmware version 1 5 0 Pressing and holding keys adds further functions to the door entry monitor Carry out the procedur...

Страница 5: ...s Loudspeaker 40 x 20 H mm 8 Ohm 2W 40 x 20 H mm 8 Ohm 2W Technologies implemented Full Duplex Full Duplex ELECTRICAL SPECIFICATIONS Type of power supply Power supply via video entry bus Power supply...

Страница 6: ...6 Installation Installed in flush mounted box art 6117 3 160 cm 130 cm 2 14 2 cm 14 7 cm 1 2 1 6 Lmax 10 cm Lmin 6 cm 5 2 3 4 5 1 4 1 1 2 CLACK 2 9 2 1 8 2 1 7 1 2 DISASSEMBLY...

Страница 7: ...ting in 503 series box round box 2 1 7 2 1 6 1 2 3C 2 1 3B Lmax 7 cm Lmin 6 5 cm 4A with Art 6620 2 1 5A with Art 6620 1 2 1 2 CLACK 8 1 2 DISASSEMBLY Art 6620 optional 160 cm 130 cm 2 2 1 3A with Art...

Страница 8: ...A 12V IN 2 1 IN 2 1 P F C L L P F C S S C N O N C 20 m MAX Connect a single call repetition device for each user code If inductive loads are connected the connection of 470nF capacitance in parallel w...

Страница 9: ...t DIP 8 of S2 to ON S2 1 2 3 4 6 7 5 8 S2 1 2 3 4 6 7 5 8 Power supply management For correct power supply management set S2 DIP 7 in accordance with the type of system and its configuration in system...

Страница 10: ...phone call PAN Priority call to switchboard not available in KIT systems NULL No function PROG With these S2 DIP switch settings the buttons control the programmed functions as in the Advanced config...

Страница 11: ...iguration table 4 Set the S1 DIP switches according to the call address of the desired apartment See Addressing table on page 17 5 Press and release the button to be associated with the function Corre...

Страница 12: ...g the next key by repeating the process from step 5 onwards 7 Exit programming mode by setting S2 DIP switch 6 to OFF LED switches off S2 8 Set S2 DIP switches 1 2 3 4 to ON 9 Return S1 DIP switches t...

Страница 13: ...g S2 DIP switch 6 to OFF LED switches off S2 7 Set S2 DIP switches 1 2 3 4 to ON 8 Return S1 DIP switches to the original combination 1 Take note of the S1 DIP switch settings 2 To enter programming m...

Страница 14: ...tch combination in which the desired functions corresponding to the buttons you want to program appear then set the S2 DIP switches Example For button 4 Self Activation AI and button 5 Call to Seconda...

Страница 15: ...is busy 2 Press and release Once 1 confirmation tone is emitted to change the ringtone for calls from the external entrance panel twice 2 confirmation tones are emitted to change the ringtone for call...

Страница 16: ...on the system type that best meets your requirements Simplebus2 audio video kit with power supply unit art 1209 for the creation of audio video systems for individual residences Simplebus2 audio vide...

Страница 17: ...8 14 2 3 4 44 3 4 6 74 2 4 7 104 4 6 7 134 2 3 8 164 3 6 8 194 2 7 8 224 6 7 8 15 1 2 3 4 45 1 3 4 6 75 1 2 4 7 105 1 4 6 7 135 1 2 3 8 165 1 3 6 8 195 1 2 7 8 225 1 6 7 8 16 5 46 2 3 4 6 76 3 4 7 10...

Отзывы: