13
Generic actuator, coded actuator
Coded
actuator
: button programming
Generic
actuator
: button programming
1.
Take note of the S1 DIP-switch settings.
2.
To enter programming mode, set S2 DIP-switch 6 to ON.
» the LED
flashes
S2
3.
Refer to the table
to identify a DIP-switch combination in which the actuator function (ACT)
corresponding to the button you want to program appears, then set the S2 DIP-switches.
4.
Set all the S1 DIP-switches to the ON position.
S1
5.
Press and release the button to be associated with the function.
» Correct procedure indication: the LED
flashes for a few seconds and a confirmation tone sounds.
6.
Exit programming mode by setting S2 DIP-switch 6 to OFF.
» LED
switches off
S2
7.
Set S2 DIP-switches 1-2-3-4 to ON.
8.
Return S1 DIP-switches to the original combination.
1.
Take note of the S1 DIP-switch settings.
2.
To enter programming mode, set S2 DIP-switch 6 to ON.
» the LED
flashes
S2
3.
Refer to the table
to identify a DIP-switch combination in which the actuator function (ACT)
corresponding to the button you want to program appears, then set the S2 DIP-switches.
4.
Set the S1 DIP-switches with the desired code, according to
5.
Press and release the button to be associated with the function.
» Correct procedure indication
: the LED
flashes for a few seconds and a confirmation tone sounds
6.
Exit programming mode by setting S2 DIP-switch 6 to OFF.
» LED
switches off
S2
7.
Set S2 DIP-switches 1-2-3-4 to ON.
8.
Return S1 DIP-switches to the original combination.