4.5 CHANGING MONITOR RINGTONES
1.
Keep the
button pressed until a confirmation tone is emitted (this operation is only possible with the system in stand-
by; otherwise the signalling LED will flash to warn the user)
2.
Press and release the
button:
once
(1 confirmation tone is emitted) to change the ringtone of calls from the external unit.
twice
(2 confirmation tones are emitted) to change the ringtone for calls from the switchboard.
3 times
(3 confirmation tones are emitted) to change the ringtone for intercom calls made from the internal unit.
4 times
(4 confirmation tones are emitted) to change the floor door (“CFP”) call ringtone.
Any further pressing of the
repeats the sequence described above.
3.
Press and release button 1 to scroll through the various available ringtones in sequence.
4.
Press button 2 to confirm selection of the last ringtone heard and to exit (at any time) the monitor ringtone change mode.
On exiting the monitor ringtone selection mode a confirmation tone will be emitted.
4.6 CONFIGURATION EX-DSME
4.6.1 External unit addressing
Set the
S1
DIP-switches corresponding to the address that you want to set as shown in the table below
EXTERNAL UNIT ADDRESSING
DIP 1
DIP 2
DIP 3
CODE
0
0
0
0 *
1
0
0
1
0
1
0
2
0
0
1
3
* default
4.6.2 Function programming
Set the
S1
DIP-switches corresponding to the function that you want to programme as shown in the table below
DIP S1
FUNCTION
DIP 4
The lock-release relay and the second relay are controlled by 2 separate buttons (e.g. lock-release button and
actuator button)
*
The lock-release relay and the second relay are controlled by a single button (e.g. lock-release button)
DIP 5
lock-release activation time and relay activation time: 8 sec
*
lock-release activation time and relay activation time: 2 sec
DIP 6
confirmation tones (call, lock-release, relay, audio enabled): disabled
*
confirmation tones (call, lock-release, relay, audio enabled): enabled
DIP 7
Camera lighting LED: disabled
*
Camera lighting LED: enabled
DIP 8
reset wait time: 1 sec.
*
reset wait time: 10 sec.
* default
Содержание HFX-9000M
Страница 25: ...25 EN 1 3 4 2 5 3 4 SURFACE MOUNTING OF THE POWER SUPPLY ART 1209 8...
Страница 67: ...67 FR 1 3 4 2 5 3 4 MONTAGE DE SURFACE DE L ALIMENTATION ART 1209 8...
Страница 88: ...88 ES...
Страница 110: ...110 ES 1 3 4 2 5 3 4 MONTAJE EN SUPERFICIE DE LA ALIMENTACI N ART 1209 8...
Страница 129: ...2 ed rev1 07 2018 cod 2G40002177 w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy...