Programming siren sound duration
The sound time of the piezoelectric siren can be programmed via the SW4 switch of the Siren Time
according to the following table:
SW-4
ON
Follow Siren input ON time (max sound time 15 minutes)
OFF
60 seconds
AND function for inputs
Using the SW6 switch, you can choose how the smoke generator is activated according to the
following table:
SW-6
ON
The smoke generator is activated only if the smoke input IN FUM is alarmed
when the siren input is already alarmed.
OFF
The smoke generator is activated immediately when the smoke input IN FUM
is alarmed.
Anti-opening and anti-tear Tamper
The anti-opening and anti-tear tamper refer to a single OUT TAMP output. In Normal state (closed
enclosure and anti-tear switch engaged) the output is Normally Closed to a Zero Voltage (GND). In
case of anomaly, the output is an Open Contact.
Tear control can be enabled/disabled using the SW5 switch as per table:
SW-5
ON
Enabled
OFF
Disabled
Meaning of LED
The activity and status of the device are highlighted by a multicolor LED at the bottom of the body
and by the status of the outputs “USED-UP SMOKE GENERATOR” and “ERROR”.
According to the following scheme, the system status information is shown every 6 seconds.