background image

 

  

 

 

 

 

 

 

 

 

USER MANUAL 

 
 
 

 

ART. DT12EAM  

 

Dual-Tech Sensor Antimask function 

Содержание DT12EAM

Страница 1: ...USER MANUAL ART DT12EAM Dual Tech Sensor Antimask function...

Страница 2: ...Temperature compensation Microcontroller signal processing Anti mask mechanism for PIR lens Front and back tamper protection Unique waterproof and sealed plastic design Detection Range 12m Detects hum...

Страница 3: ...or which includes a large LED indicator that can be easily observed from long distances to provide indication of intrusion Using the supplied mounting bracket the DT12EAM can be easily mounted to wall...

Страница 4: ...2 Detection Pattern The DT12EAM has a 90 top view PIR and MW detection pattern with 12m detection distance when installed at 2 4m above the ground surface DT12EAM...

Страница 5: ...ature changes Mounted at more than 10 from the vertical or horizontal plane Facing metal doors Near direct sources of heat or airflow Clear all physical obstacles from the detection area e g plants la...

Страница 6: ...ft 3 Make sure to attach the metal bracket to a leveled straight and firm wall leaving 10cm 3 9 inches from the top and 10cm 3 9 inches from both sides for easy installation and maintenance 4 Placing...

Страница 7: ...rews 9 Insert wires through provided access hole and wiring channels 10 Attach the sealing sponge pad to the wire opening from the rear side after the wires have been connected and prior to final prod...

Страница 8: ...LARM 1 1 8 k J7 ALARM 2 3 3 k J7 ALARM 3 DIDN T USE J7 ALARM 4 DIDN T USE J6 AM TROUBLE 1 DIDN T USE J6 AM TROUBLE 2 3 3 k J6 AM TROUBLE 3 DIDN T USE J6 AM TROUBLE 4 DIDN T USE J8 2 4 Connessione inte...

Страница 9: ...rminal 6 7 Marked AM FAIL These are the output of the anti mask and Trouble relay N C and N O Will switch if one from the following scenario happens The supply voltage is under 8 5v Mask detection wil...

Страница 10: ...sensitivity PIR sensitivity Anti mask module connector MW antenna PIR sensor 6 Settings Adjustments 6 1 Detection beam direction The DT12EAM detection beam direction is fixed As a result it is recomm...

Страница 11: ...immunity 4 On Off 8 2 2 MW Sensitivity adjustment The MW has 4 configurable levels by SW1 Position 1 Position 2 up up High sensitivity more suitable for indoor application up down High sensitivity fo...

Страница 12: ...Yellow LED indicates MW detection 3 Red LED alarm indication logic AND of both MW and PIR The installer has an option to control LEDs operation using the LED control on SW2 position 1 between ON and...

Страница 13: ...er direct sunlight the DT12EAM will made the self calibration 30 minutes after the sun light intensity will decrease 10 Operation Note Connect the DT12EAM to a positive Voltage output of 9 6 16VDC Use...

Страница 14: ...ned ON Allow 5 sec between each test for the detector to stabilize Upon installation the unit should be thoroughly tested to verify proper operation Walk across the entire area where coverage is desir...

Страница 15: ...ith 10 Ohm Series protection resistors Opens when cover is removed from unit s base Warm up Period 30sec 5sec RF Immunity 10 V m plus 80 AM from 80 MHz to 2GHz Electrostatic Immunity 6kV contact 8kV a...